Vokera Eclipse ESC Fault codes & diagnostics

52 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Gas Discontinued
GC Number 47-094-24
Download the Vokera Eclipse ESC manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
4 Emergency 47 High 1 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-094-24 Eclipse ESC 1996–2010

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 52 documented codes

Tap any card for details

00

Your boiler has detected a flame inside when it should be turned off, which is a safety mechanism preventing it from firing up again.

Emergency Engineer only £120-250

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Flame sensing electrode

Related codes

01

Your boiler has detected an electrical fault in its control system, which means it has safely shut itself down to prevent damage to its internal components.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

02

Your boiler is attempting to start but cannot detect the flames necessary to heat your water or radiators.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Flame rectification probe

Related codes

03

Your boiler's main control computer is experiencing an internal error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

04

Your boiler has detected a serious internal operating fault and has shut itself down completely for safety reasons.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Ignition lead
  • Gas valve

Related codes

05

Your boiler's internal computer has encountered an error it cannot recover from, meaning the boiler has stopped working to protect itself.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

06

Your boiler's main control computer is experiencing an internal error and cannot operate safely.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB

Related codes

07

Your boiler's electronic brain has detected a critical internal error and has shut down for safety.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

08

Your boiler has detected a failure within its main internal computer, preventing it from operating safely.

High Engineer only £250-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

09

Your boiler's main control computer is experiencing an internal error and cannot safely operate your heating or hot water.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB

Related codes

Showing 11–20 of 52
10

Your boiler's main internal computer has detected a serious internal error and has shut down for safety.

High Engineer only £250-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

11

Your boiler's main computer control panel is failing to process instructions correctly, which has caused the system to shut down for safety reasons.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

12

Your boiler has stopped working because the internal waste water drain is blocked, which is a safety feature to prevent harmful gases from escaping.

High Engineer only £80-150

Parts commonly replaced

  • Condensate trap
  • Condensate pipework

Related codes

13

Your boiler's internal computer is experiencing a critical error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

14

Your boiler's internal computer is experiencing a critical error and can no longer safely control the system, meaning your heating and hot water will not function.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

15

Your boiler's main control computer is experiencing an internal error and cannot safely operate the heating or hot water system.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

16

Your boiler has detected an internal electronic error within its main control brain, meaning it has safely shut down to prevent incorrect operation.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

17

Your boiler's main control computer is experiencing an internal error and cannot operate safely.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

18

Your boiler has detected that the water inside the system has become dangerously overheated and has shut itself down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • NTC thermistor
  • Primary heat exchanger
  • Pump

Related codes

19

Your boiler has detected that the water returning to it is dangerously hot, causing it to shut down to prevent damage or overheating.

High Engineer only £150-250

Parts commonly replaced

  • Return NTC sensor
  • Primary heat exchanger
  • Pump

Related codes

Showing 21–30 of 52
24

Your boiler has detected that the water temperature sensors are reading the pipes in the wrong order, preventing it from safely heating your home.

High Engineer only £120-200

Parts commonly replaced

  • NTC Thermistor
  • Wiring harness
  • PCB

Related codes

25

Your boiler is overheating because water is not flowing through it properly, so it has shut itself down to prevent damage.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Diverter Valve
  • Primary Heat Exchanger

Related codes

26

Your boiler has detected that the gas supply pressure coming into the unit is too low to operate safely and effectively.

Emergency Engineer only £100-250

Parts commonly replaced

  • Gas valve
  • Gas regulator

Related codes

28

Your boiler has stopped working because it cannot detect that the internal air circulation fan is running, which is a key safety requirement for operation.

High Engineer only £150-300

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • PCB (Printed Circuit Board)

Related codes

29

Your boiler has stopped working because it has lost connection to the internal fan that safely removes combustion gases.

High Engineer only £150-300

Parts commonly replaced

  • Boiler Fan
  • Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

30

Your boiler has detected an internal computer error and has safely shut down to prevent any further issues.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB
31

Your boiler's water flow sensor is reporting an internal electrical fault, which means the system cannot safely detect if water is moving through the pipes, causing it to shut down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

32

Your boiler has stopped working because it is unable to accurately measure the temperature of the water returning to it, causing the system to shut down for safety.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

33

Your boiler has detected an electrical fault in a temperature sensing component, causing it to stop working to ensure your safety.

High Engineer only £120-220

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

36

Your boiler has lost the ability to detect the flow of water, meaning it cannot safely heat your home or provide hot water.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

Showing 31–40 of 52
37

Your boiler has lost the connection to the sensor that monitors the water temperature returning to the unit, causing it to stop heating as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

38

Your boiler has lost the connection to a sensor responsible for monitoring the cold water entering the system, meaning it cannot accurately judge the temperature and has shut down as a precaution.

High Engineer only £120-220

Parts commonly replaced

  • Inlet sensor
  • Wiring harness

Related codes

41

Your boiler's main control computer is experiencing an internal error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB

Related codes

42

Your boiler's main control computer is experiencing an internal error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

44

Your boiler's main control computer is experiencing an internal error, meaning the system has stopped working to prevent further damage.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

60

Your boiler's internal computer has encountered a critical error and can no longer safely control the heating or hot water functions.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

61

Your boiler's internal computer has encountered a serious error and is unable to operate safely, meaning you currently have no heating or hot water.

High Engineer only £250-450

Parts commonly replaced

  • Main Control PCB

Related codes

65

Your boiler is struggling to push air through its system because the internal fan is not spinning at the right speed, causing the unit to stop working for safety reasons.

High Engineer only £150-300

Parts commonly replaced

  • Flue fan assembly
  • Fan wiring harness
  • Printed Circuit Board (PCB)

Related codes

202

Your boiler has stopped because it is not receiving enough gas to stay lit.

High DIY-safe £90-180

What to check first

  1. Check if other gas appliances in your home, such as the cooker, are working.
  2. Verify that your gas supply meter tap is fully open and the emergency control valve has not been accidentally tripped.
  3. Check if your prepayment gas meter has run out of credit and needs topping up.
  4. If you recently had gas work done, try resetting the boiler once the gas supply is confirmed.

Parts commonly replaced

  • Gas valve
  • Gas regulator

Related codes

436

Your boiler has lost the connection to the part that monitors water movement, so it has safely shut down to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • Flow sensor harness
  • Flow sensor assembly

Related codes

Showing 41–50 of 52
437

Your boiler has lost the signal from a temperature sensor that monitors the water returning to the system, causing the unit to stop working as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

438

Your boiler has lost the connection to the sensor that monitors your incoming cold water, meaning it cannot properly regulate the temperature of your hot water supply.

Medium Engineer only £120-200

Parts commonly replaced

  • Cold water sensor wiring harness
  • NTC sensor

Related codes

918

Your boiler has temporarily stopped circulating water because the internal pump is stuck or a water valve has been accidentally closed.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • Flow/return isolation valves

Related codes

E18

Your boiler has detected that the water inside the unit is dangerously hot and has shut itself down to prevent damage or overheating.

Emergency Engineer only £150-300

Parts commonly replaced

  • NTC thermistor
  • Primary heat exchanger
  • Central heating pump
E19

Your boiler has detected that the water returning from your radiators is dangerously hot, causing it to shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Return NTC sensor
  • Pump
  • Primary heat exchanger

Related codes

E24

Your boiler has temporarily stopped working because the water inside is getting too hot in one part compared to another, usually due to a blockage in the flow.

High Engineer only £150-300

Parts commonly replaced

  • Circulating pump
  • Heat exchanger
  • NTC thermistor

Related codes

E26

Your boiler is failing to light the flame or maintain it, meaning you likely have no heating or hot water at the moment.

High Engineer only £150-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB
E30

Your boiler has detected that the water returning from your radiators is significantly hotter than the water leaving it, indicating a potential blockage or water flow issue.

High Engineer only £150-300

Parts commonly replaced

  • Return thermistor sensor
  • Flow thermistor sensor
  • Circulating pump

Related codes

E65

Your boiler has detected that the internal fan responsible for safely pushing out exhaust gases is not spinning fast enough.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue gas fan
  • Printed Circuit Board (PCB)

Related codes

Fan fault

Your boiler has detected that the internal fan responsible for safely exhausting fumes is not turning on, so it has shut down to prevent unsafe operation.

High Engineer only £180-350

Parts commonly replaced

  • Flue fan assembly
  • Fan harness and wiring
  • Printed Circuit Board (PCB)
Showing 51–52 of 52
Ignition fault

Your boiler is failing to light the flame needed to produce heat and hot water despite several attempts.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB
  • Condensate trap
Pump failure

Your boiler has detected that the internal mechanism responsible for circulating hot water around your system has stopped working, meaning you currently have no heating or hot water.

High Engineer only £180-350

Parts commonly replaced

  • Central heating pump
  • Pump capacitor