Vokera Eclipse ESS Fault codes & diagnostics

29 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Gas Discontinued
GC Number 41-094-10
Download the Vokera Eclipse ESS manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
2 Emergency 27 High

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-094-10 Eclipse ESS 1996–2010

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 29 documented codes

Tap any card for details

0 00

Your boiler is temporarily locked out because it is detecting a flame inside when it shouldn't be burning.

High Engineer only £150-£300

Parts commonly replaced

  • Flame sensor
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

2 02

Your boiler has tried to start up, but it cannot detect a flame to keep the heating or hot water running safely.

High Engineer only £100-£250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

4 36

Your boiler has lost the connection to the part that monitors water movement, so it has safely shut down to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • Flow sensor harness
  • Flow sensor assembly

Related codes

4 37

Your boiler has lost the signal from a temperature sensor that monitors the water returning to the system, causing the unit to stop working as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

12

Your boiler has stopped working because the internal waste water drain is blocked, which is a safety feature to prevent harmful gases from escaping.

High Engineer only £80-150

Parts commonly replaced

  • Condensate trap
  • Condensate pipework

Related codes

18

Your boiler has detected that the water inside the system has become dangerously overheated and has shut itself down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • NTC thermistor
  • Primary heat exchanger
  • Pump

Related codes

19

Your boiler has detected that the water returning to it is dangerously hot, causing it to shut down to prevent damage or overheating.

High Engineer only £150-250

Parts commonly replaced

  • Return NTC sensor
  • Primary heat exchanger
  • Pump

Related codes

24

Your boiler has detected that the water temperature sensors are reading the pipes in the wrong order, preventing it from safely heating your home.

High Engineer only £120-200

Parts commonly replaced

  • NTC Thermistor
  • Wiring harness
  • PCB

Related codes

25

Your boiler has temporarily stopped working because the water inside is heating up much faster than normal.

High Engineer only £150-300

Parts commonly replaced

  • Circulating pump
  • NTC temperature sensor
  • Heat exchanger

Related codes

26

Your boiler has detected that the gas supply pressure coming into the unit is too low to operate safely and effectively.

Emergency Engineer only £100-250

Parts commonly replaced

  • Gas valve
  • Gas regulator

Related codes

Showing 11–20 of 29
28

Your boiler has stopped working because it cannot detect that the internal air circulation fan is running, which is a key safety requirement for operation.

High Engineer only £150-300

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • PCB (Printed Circuit Board)

Related codes

29

Your boiler has stopped working because it has lost connection to the internal fan that safely removes combustion gases.

High Engineer only £150-300

Parts commonly replaced

  • Boiler Fan
  • Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

30

Your boiler has detected an internal computer error and has safely shut down to prevent any further issues.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB
31

Your boiler's water flow sensor is reporting an internal electrical fault, which means the system cannot safely detect if water is moving through the pipes, causing it to shut down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

32

Your boiler has stopped working because it is unable to accurately measure the temperature of the water returning to it, causing the system to shut down for safety.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

33

Your boiler has detected an internal computer error and has safely shut down to prevent any further issues.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB
36

Your boiler has lost the ability to detect the flow of water, meaning it cannot safely heat your home or provide hot water.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

37

Your boiler has lost the connection to the sensor that monitors the water temperature returning to the unit, causing it to stop heating as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

38

Your boiler has detected an internal computer error and has safely shut down to prevent any further issues.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)
41

Your boiler's main control computer is experiencing an internal error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB

Related codes

Showing 21–29 of 29
42

Your boiler's main control computer is experiencing an internal error and cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

44

Your boiler's main control computer is experiencing an internal error, meaning the system has stopped working to prevent further damage.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

60

Your boiler's internal computer has encountered a critical error and can no longer safely control the heating or hot water functions.

High Engineer only £250-450

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

61

Your boiler's internal computer has encountered a serious error and is unable to operate safely, meaning you currently have no heating or hot water.

High Engineer only £250-450

Parts commonly replaced

  • Main Control PCB

Related codes

65

Your boiler is struggling to push air through its system because the internal fan is not spinning at the right speed, causing the unit to stop working for safety reasons.

High Engineer only £150-300

Parts commonly replaced

  • Flue fan assembly
  • Fan wiring harness
  • Printed Circuit Board (PCB)

Related codes

202

Your boiler has detected trapped air in the gas supply pipe, which prevents it from igniting safely.

Emergency Engineer only £90-180
436

Your boiler has lost the connection to the part that monitors water movement, so it has safely shut down to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • Flow sensor harness
  • Flow sensor assembly

Related codes

437

Your boiler has lost the signal from a temperature sensor that monitors the water returning to the system, causing the unit to stop working as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

918

Your boiler has detected that the water valves underneath it have been closed, preventing water from flowing through the system properly.

High DIY-safe

What to check first

  1. Locate the flow and return isolation valves directly beneath your boiler.
  2. Check that the levers or handles on these pipes are turned fully parallel to the pipes in the open position.
  3. If any valve was closed, open it fully and then reset your boiler.

Related codes