The domestic water demand indicator will flash (approximately five times per second).
Worcester Bosch 25Si LPG Fault codes & diagnostics
7 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 47-311-50 | 25Si - LL RSF | 1999–2002 |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 7 documented codes
Tap any card for details
Fan or flue related issue; check pressure switch operation, silicon tubes, flue restrictions, and wiring.
Boiler fails to ignite; check gas supply, spark electrode/HT leads, flame sensor, gas valve, and wiring.
The central heating demand indicator will flash slowly (approximately once per second).
Both the central heating and the hot water demand indicators will flash together.
Boiler has overheated; check water pressure, venting of air, pump operation, primary sensor, and overheat thermostat.
Fault detected in DHW or CH sensor/wiring; check sensor continuity, resistance (1 kohm - 30 kohm), and fitting.