High Lockout
POINT D on Worcester Bosch Highflow 550 CDi

Your boiler is failing to ignite the burner at the required power, meaning it cannot provide heating or hot water.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Burner does not instantly operate at or near maximum gas pressure / 230V at pin 1 of terminal X4 (Brown wire)

What causes this fault?

This fault occurs when the boiler's control system attempts to fire the burner at full power but fails to detect the necessary electrical signal or gas pressure. It is typically caused by a failing gas valve that cannot open fully or a fault within the internal control box that prevents power from reaching the ignition components. In some cases, a loose or damaged wiring connection between these two parts is the root cause.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →