Baxi Combi 130 HE Fault codes & diagnostics

29 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 30 kW 2005-2010 Discontinued
GC Number 47-075-04

Replaced by: Baxi Duo-tec Combi HE

Download the Baxi Combi 130 HE manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
25 High 3 Medium 1 Low

All 29 documented codes

Tap any card for details

24

Your boiler has stopped working because it cannot light the flame or the internal drainage pipe is backed up with water.

High DIY-safe £90-280

What to check first

  1. Check if your shared external white drainage pipe is frozen or blocked.
  2. If frozen, pour warm (not boiling) water over the pipe to clear the ice.
  3. Press the reset button once to see if the boiler restarts.

Parts commonly replaced

  • Flame sensing electrode
  • Ignition lead
  • Gas valve
  • Condensate trap
25

Your boiler has shut down because a safety sensor has detected that the system is starting to overheat.

High DIY-safe £120-£350

What to check first

  1. Ensure all radiator valves are fully open
  2. Check that the system water pressure is between 1.0 and 1.5 bar
  3. Switch the selector dial to the reset position for five seconds and release

Parts commonly replaced

  • Safety Thermostat (Overheat Limit)
  • Circulation Pump
  • Main Heat Exchanger (Descaling)
26

Your boiler has stopped working because the fan cannot safely clear exhaust fumes from the system.

High Engineer only £150-£350

Parts commonly replaced

  • Fan assembly
  • Air pressure switch
  • Venturi tube
27

Your boiler is struggling to circulate water, which is usually caused by the system pressure being too low or a problem with the internal pump.

High DIY-safe £180-350

What to check first

  1. Check the pressure gauge on the front of the boiler; it should be between 1.0 and 1.5 bar.
  2. If the pressure is too low, use the filling loop underneath the boiler to top it up.
  3. Reset the boiler by turning the selector switch to 'R' for five seconds.

Parts commonly replaced

  • Circulating Pump
  • Water Pressure Sensor
  • Expansion Vessel Re-charge

Related codes

28

Your boiler is likely struggling to monitor or control the temperature of your hot water properly due to a faulty internal sensor.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Sensor
  • Sensor wiring harness
29

Your boiler has detected an issue with the sensor that monitors the temperature of the water used for your radiators, causing the heating to stop working correctly.

Medium Engineer only £90-160

Parts commonly replaced

  • Central Heating NTC Temperature Sensor
  • Sensor Wiring Harness
Dry-Fire

Your boiler has detected there is not enough water flowing through it to safely heat up, which has caused it to shut down to prevent overheating.

High DIY-safe £120-350

What to check first

  1. Check the pressure gauge on the front of the boiler or under the sink
  2. If the pressure is below 1.0 bar, use the filling loop to top it up to 1.5 bar
  3. Ensure all radiator valves are open and turn the selector switch to reset

Parts commonly replaced

  • Circulation pump
  • Flow switch
  • Pressure sensor
E06

Your boiler has lost the ability to accurately measure the temperature of the water it is heating for your taps, so it has stopped providing hot water to ensure safety.

High Engineer only £120-200

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Thermistor
  • Wiring harness

Related codes

Flow Thermistor

Your boiler has detected an issue with the sensor that monitors the temperature of the water leaving the unit, meaning it cannot heat your home or water safely.

High Engineer only £90-160

Parts commonly replaced

  • Flow Thermistor (NTC Sensor)
  • Wiring Harness
  • Main PCB
Showing 11–20 of 29
Ignition Lockout

Your boiler has failed to light the flame and has safely shut down to prevent gas from building up inside the unit.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)
L0

Your boiler has failed to start up or stay lit and has stopped working as a safety precaution.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)
L2

Your boiler has stopped working because it cannot measure the temperature of the water flowing through it, meaning it doesn't know when to turn the heat on or off.

High Engineer only £120-200

Parts commonly replaced

  • NTC Flow Thermistor
  • Wiring harness

Related codes

L3

Your boiler is struggling to accurately measure the temperature of the water returning to it, so it has shut down to prevent potential damage.

High Engineer only £120-220

Parts commonly replaced

  • Return NTC thermistor
  • Wiring harness

Related codes

L4

Your boiler's electronic control panel is experiencing a communication error, meaning it cannot properly regulate the heating or hot water functions.

High Engineer only £150-300

Parts commonly replaced

  • Intellistat Control Board
  • Wiring Harness
L5

Your boiler has detected that the internal fan is operating at a temperature higher than it should, causing the system to stop working to protect itself from potential damage.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • PCB
L6

Your boiler's water circulation system has stopped working, meaning it cannot move heat around your home or to your taps.

High Engineer only £180-350

Parts commonly replaced

  • Circulation pump
  • Pump wiring harness
  • Printed Circuit Board (PCB)
L7

Your boiler has detected that it is running without enough water inside, which prevents it from operating safely to protect the system from overheating.

High DIY-safe £80-150

What to check first

  1. Locate the external filling loop, usually two braided hoses connected to the pipework under the boiler.
  2. Open the filling valve slowly until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.
  3. Close the valve tightly to prevent the system from over-pressurising.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Expansion vessel
L8

Your boiler has detected that it is running without enough water inside, which prevents it from firing up to provide your heating or hot water.

High DIY-safe £80-120

What to check first

  1. Locate the external filling loop, usually a silver braided hose under the boiler.
  2. Open the valves on the filling loop to allow cold mains water into the boiler.
  3. Monitor the pressure gauge on the front panel until the needle reaches the green zone, typically between 1.0 and 1.5 bar.
  4. Close both valves tightly and restart the boiler.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Expansion vessel
L9

Your boiler has detected that the internal components responsible for clearing exhaust gases are not working correctly, so it has safely shut down to prevent any risk.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed Circuit Board (PCB)
Showing 21–29 of 29
Ld

Your boiler has detected that the water inside it has become dangerously hot and has shut itself down to prevent damage.

High Engineer only £150-300

Parts commonly replaced

  • NTC Sensor
  • Primary Heat Exchanger
  • Pump
LE

Your boiler has detected that the ventilation system is getting too hot and has automatically shut itself down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • Fan overheat thermostat
  • Flue fan assembly
  • Wiring harness

Related codes

LF

Your boiler is unable to drain away the water it creates during normal operation, so it has shut down to prevent internal flooding.

High Engineer only £90-160

Parts commonly replaced

  • Condensate trap
  • Condensate pipework
  • Siphon
Lh

Your boiler has detected an internal communication error with its control panel, which means it will likely stop heating or providing hot water to prevent unpredictable operation.

High Engineer only £250-400

Parts commonly replaced

  • Display PCB
  • Main Control PCB
  • Wiring harness
Lt

Your boiler is failing to detect when you turn on a hot tap, so it isn't heating the water for your shower or kitchen faucet.

Medium Engineer only £120-220

Parts commonly replaced

  • DHW Flow Switch
  • Diaphragm assembly
Overheat Lockout

Your boiler has switched itself off because it has become too hot to operate safely and requires a manual reset once it has cooled down.

High DIY-safe £100-350

What to check first

  1. Ensure all radiator valves are fully open to allow water to flow.
  2. Wait for the boiler to cool down for at least 30 minutes.
  3. Turn the selector switch to the 'Reset' position and hold for 5 seconds before turning it back to 'On'.

Parts commonly replaced

  • Circulating Pump
  • Overheat Thermostat
  • Main Heat Exchanger
PCB Fault

Your boiler's internal computer brain has detected an electronic error and has stopped working to protect the system.

High Engineer only £250-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Wiring Harness
Return Thermistor

Your boiler has detected a problem with the sensor that monitors the water temperature coming back into the unit, causing it to stop running for safety.

High Engineer only £90-180

Parts commonly replaced

  • Return Thermistor (NTC Sensor)
  • Wiring Harness
  • Main PCB
Wiring Harness

Your boiler has stopped working because of a loose connection or a fault in the internal electrical wiring between the main control board and the internal components.

High Engineer only £120-250

Parts commonly replaced

  • Main Wiring Harness
  • 8-way PCB Connector
  • Printed Circuit Board (PCB)

3 operating states & engineer diagnostics