Severity at a glance

Each cell = one fault code. Hover to identify.
17 High 1 Medium 1 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-583-43 ADVANCE 25C 2017–present

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 19 documented codes

Tap any card for details

An 11

Your boiler is struggling to light its burner or cannot detect that a flame has been successfully lit, preventing it from heating your water.

High DIY-safe £90-280

What to check first

  1. Check if other gas appliances, like your hob, are working to ensure gas is reaching the property.
  2. Verify that your prepaid gas meter has credit if applicable.
  3. Press and hold the 'Reset' button for five seconds to see if the boiler restarts.

Parts commonly replaced

  • Ignition Electrode
  • Flame Sensing Probe
  • Gas Valve

Related codes

Er 01

Your boiler has temporarily stopped working for safety reasons and needs to be manually reset to get it going again.

High DIY-safe £100-250

What to check first

  1. Locate the reset button on your boiler's control panel.
  2. Press and hold the reset button for approximately 3 to 5 seconds.
  3. Wait to see if the boiler fires up normally; if the error returns, do not keep resetting it.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

Er 02

Your boiler has temporarily stopped working for safety reasons and needs to be reset.

High DIY-safe £90-200

What to check first

  1. Locate the reset button or turn the mode selector switch to the reset position.
  2. Hold the reset button for 2 to 5 seconds and release it.
  3. Wait to see if the boiler fires up normally; do not repeat this more than three times.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

Er 03

Your boiler has temporarily stopped working as a safety precaution and needs to be reset.

High DIY-safe £90-250

What to check first

  1. Locate the reset button or turn the mode dial to the reset position on your Biasi Advance 25C.
  2. Press and hold the reset button for approximately 3 to 5 seconds.
  3. Wait to see if the boiler fires up normally; if the code returns, do not keep resetting it.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed circuit board (PCB)

Related codes

Er 04

Your boiler has temporarily stopped working as a safety precaution to prevent potential damage.

High DIY-safe £100-250

What to check first

  1. Locate the reset button or turn the mode dial to the reset position on your Biasi boiler.
  2. Hold the reset button down for about 2 to 5 seconds and release it.
  3. Wait a moment to see if the boiler fires up normally; if the error returns immediately, do not keep resetting it.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed circuit board (PCB)

Related codes

Er 05

Your boiler has safely shut itself down due to a general safety lock-out, meaning it has stopped working until the underlying issue is resolved.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed circuit board (PCB)

Related codes

Er 06

Your boiler has temporarily stopped working for safety reasons and needs to be reset.

High DIY-safe £100-£250

What to check first

  1. Locate the reset button on your boiler control panel.
  2. Press and hold the reset button for about 5 seconds.
  3. Wait to see if the boiler fires up normally; do not repeat this more than twice.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

Er 07

Your boiler has temporarily shut itself down for safety reasons and stopped providing heating and hot water.

High Engineer only £90-250

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Ignition electrode

Related codes

Er 08

Your boiler has safely shut itself down due to a recurring internal safety lock-out.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Electrode assembly
  • Gas valve

Related codes

Er 09

Your boiler has safely shut itself down due to a general lockout fault that requires a professional engineer to diagnose and reset.

High Engineer only £100-250

Parts commonly replaced

  • Main PCB
  • Ignition Lead
  • Gas Valve

Related codes

Er 10

Your boiler has safely shut down and locked itself to prevent potential risks, meaning you currently have no heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • PCB
  • Gas valve
  • Ignition electrode

Related codes

Er 11

Your boiler is failing to detect a flame, which means it cannot light safely to provide heating or hot water.

High DIY-safe £100-280

What to check first

  1. Check if other gas appliances (like a hob) are working to ensure gas is reaching the property.
  2. Ensure your gas meter has credit if you use a pre-payment meter.
  3. Gently press the 'Reset' button on the front control panel to see if the boiler restarts.

Parts commonly replaced

  • Ignition Electrode
  • Ionisation Probe
  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

Er 12

Your boiler has sensed a problem with the internal sensor that monitors the temperature of the water returning from your radiators.

Medium Engineer only £90-160

Parts commonly replaced

  • Central heating return NTC thermistor
  • Wiring harness

Related codes

Er 13

Your boiler has detected that the water is getting too hot too quickly because it isn't circulating through the system properly.

High DIY-safe £120-£350

What to check first

  1. Check that all radiator valves are fully open
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar
  3. Gently bleed air from your radiators using a radiator key

Parts commonly replaced

  • Circulation Pump
  • Main Heat Exchanger
  • Return Temperature Sensor

Related codes

Er 14

Your boiler has safely shut itself down due to a safety lock-out, meaning it needs to be manually reset or checked by a professional before it will work again.

High DIY-safe £90-250

What to check first

  1. Locate the reset button or dial on your Biasi boiler control panel.
  2. Press and hold the reset button for about 3 to 5 seconds.
  3. Wait to see if the boiler fires up normally; if the code returns, do not keep resetting it.

Parts commonly replaced

  • PCB
  • Ignition Electrode
  • Gas Valve

Related codes

Er 19

Your boiler is having trouble measuring the temperature of the cold water coming in, which may affect how well it heats your hot water.

Low Engineer only £90-160

Parts commonly replaced

  • DHW inlet temperature probe
  • Connecting wiring harness

Related codes

Er 25

Your boiler has temporarily stopped working for safety reasons and needs a professional to investigate the underlying cause.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed circuit board (PCB)

Related codes

Er 69

Your boiler has shut down because it has detected an electrical connection issue or an internal wiring conflict within its control system.

High Engineer only £100-£250

Parts commonly replaced

  • Main PCB
  • Wiring harness
  • External sensor

Related codes

Li 01

Your boiler has reached an excessively high temperature while trying to provide hot water and has shut down as a safety precaution.

High Engineer only £120-350

Parts commonly replaced

  • Plate heat exchanger
  • DHW temperature sensor
  • Diverter valve motor
  • Internal pump