Low
37 on Ferroli Optimax

Your boiler has detected that the water pressure is too low or fluctuating, causing it to pause for safety until it returns to a normal level.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

Technical description

Temporary shutdown fault - resets automatically as soon as the value comes back within the boiler’s normal working range

DIY fix possible

Check the pressure gauge on the front of the boiler; it should be between 1 and 1.5 bar.If the pressure is below 1 bar, locate the filling loop (usually a silver flexible hose) under the boiler.Slowly open the valves on the filling loop to add water until the gauge reaches 1.2 bar, then close the valves tightly.