Fault: Flow temperature sensor
Glow-worm EASICOM 3 25r Fault codes & diagnostics
44 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 41-019-50 | EASICOM 3 25r | 2016–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 44 documented codes
Tap any card for details
Fault: Return temperature sensor
Short circuit: Flow temperature sensor
Short circuit: Return temperature sensor
Short circuit: Cylinder temperature sensor
Short circuit: Temperature sensor for the domestic hot water cylinder
Safety shutdown: Overheating temperature reached
Safety shutdown: Temperature spread too great (NTC1/NTC2)
Safety shutdown: Temperature rise too fast
Safety shutdown: Flue gas temperature too high
Safety shutdown: Fault in flame detection
Fault: Ignition unsuccessful when starting up
Fault: Flame loss
Fan frost protection function active: Fan speed outside the tolerance values
eBUS fault: Voltage too low
Fault: Gas valve assembly control
Fault: Gas valve switch-off control
Fault: EEPROM
Fault: Electronics/sensor/analogue-to-digital converter
Fault: Electronics temperature too high
Value sent back by ASIC is incorrect (flame signal)
Fault: Unstable flame (analogue input)
Invalid product code (DSN)
Fault: Flow/return temperature sensor
Fault: Deviation in the water pressure sensor/return temperature sensor
Fault: Condensate or smoke
Interruption to DHW outlet sensor at external control
Fault: Dry fire
Fault: Flow/return temperature sensor
Fault: Temperature sensor
Fault: Underfloor heating contact
Fault: Electrodes
Fault: Gas valve assembly
Short circuit: Cylinder temperature sensor
Fault: Main PCB self-test failed
Heating mode: No requirement
Heating mode: Fan prerun
Heating mode: Pump prerun
Heating mode: Burner ignition
Heating mode: Burner on
Heating mode: Pump/fan overrun
Heating mode: Fan overrun
Heating mode: Pump overrun
Heating mode: Temporary shutdown after heating procedure
Avoid the next call-out bill
Monthly cover means no unexpected bills when your boiler breaks down.
Affiliate links. We may earn a commission at no extra cost to you.