High Lockout
NEON3 on Glow-worm Hideaway 40B

Your boiler has detected that the internal fan is spinning, but it hasn't received the signal to proceed with the next step of the ignition process.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

FAN RUNNING

What causes this fault?

This fault occurs when the boiler's control board detects the fan is spinning but the air pressure switch fails to close the electrical circuit to confirm safe airflow. The most common reasons are a blockage in the small plastic 'venturi' tubes inside the boiler or a mechanical failure within the pressure switch itself. Without this confirmation signal, the boiler will not spark for ignition as a safety precaution.

This issue is more common during the first cold spell of autumn when a boiler that has been idle over summer is suddenly forced to work at high capacity, causing older mechanical switches to stick.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →