26 High

Johnson Starley 26 Fault Code

The Johnson Starley 26 fault code means: your boiler is struggling to keep its burner lit and has shut down for safety after failing to detect a steady flame several times.. It appears on 10 Johnson Starley models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: Flame lost signal lost 5 times in 4 minutes. Flame sensing error. Failing gas pressures. Fan fault. Flue blockage. Check flame detection lead between sensor and ignition control board. Check the gas supply, does pressure fall when burner fires? Check that flue system is not blocked.
Typical repair cost £120-350 (including labour)

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Johnson Starley models that show the 26 fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Johnson Starley 26 fault code information on this page is sourced and cross-checked against the official Johnson Starley service / installation manuals for each affected model.