Main Eco Compact Combi Fault codes & diagnostics

68 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 25-30 kW 2019-present
Download the Main Eco Compact Combi manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
24 High 1 Medium 43 Unrated

All 68 documented codes

Tap any card for details

20

Your boiler is struggling to control its internal gas supply, which means it has safely shut itself down to prevent any risk of incomplete combustion.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

28

Your boiler is struggling to control the gas supply it needs to stay lit, so it has shut down to keep your home safe.

High Engineer only £150-250

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

40

Your boiler is struggling to manage the gas supply required to light the flame and heat your water, which has caused it to shut down for safety.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

103

Your boiler has lost communication with an optional safety monitoring device, which is preventing it from operating correctly.

High Engineer only £120-250

Parts commonly replaced

  • Safety Assist accessory module
  • Wiring harness
  • Main printed circuit board

Related codes

104

Your boiler has lost communication with an optional safety device, meaning it has shut down as a precaution to prevent unsafe operation.

High Engineer only £120-250

Parts commonly replaced

  • Safety Assist module
  • Wiring harness
  • Main PCB

Related codes

107

Your boiler is having a communication error with an optional safety monitoring device, which is causing the system to stop functioning as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Safety Assist accessory module
  • PCB

Related codes

110

Your boiler has detected that the water inside the heating system has become too hot and has automatically shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Pump
  • Primary Heat Exchanger

Related codes

Showing 11–20 of 68
118

Your boiler has stopped working because the water pressure inside the heating system has dropped too low to operate safely.

High DIY-safe £80-120

What to check first

  1. Locate the external filling loop or internal key under the boiler
  2. Slowly open the valves to allow mains water to enter the system
  3. Watch the pressure gauge on the front of the boiler until the needle reaches the green zone between 1.0 and 1.5 bar
  4. Close the valves firmly and check that the fault code has cleared

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure sensor

Related codes

125

Your boiler is struggling to circulate water properly or is overheating because it cannot detect the expected changes in water temperature.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • NTC Thermistor
  • Heat Exchanger

Related codes

128

Your boiler has stopped because it cannot maintain a stable flame to heat your water.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Circuit board

Related codes

133

Your boiler is failing to light because it cannot detect a flame, which may be caused by a temporary gas supply issue.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

134

Your boiler is trying to start but cannot detect a flame, likely because the gas supply is blocked or the ignition system is failing to spark.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

135

Your boiler is failing to light because it is not receiving enough gas or is having trouble sparking, meaning you currently have no heating or hot water.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

160

Your boiler has detected an issue with the system that controls the flow of gas, meaning it has shut itself down to keep your home safe.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

321

Your boiler is having trouble controlling the flow of gas needed to stay lit, so it has shut down as a safety precaution.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

Showing 21–30 of 68
Showing 31–40 of 68
E20

Your boiler has detected a fault with the internal sensor that monitors the temperature of your central heating water, causing the system to stop working as a safety precaution.

High Engineer only £90-£160

Parts commonly replaced

  • Central heating NTC temperature sensor
  • Connecting wiring harness

Related codes

Showing 41–50 of 68
E110

Your boiler has switched itself off because it has reached an unsafe temperature, usually due to a lack of water flow or a circulation problem.

High DIY-safe £100-£350

What to check first

  1. Check if your radiator valves are open
  2. Check the boiler pressure gauge and top up to 1.5 bar if low
  3. Press the 'R' or 'Reset' button for 2 seconds once the boiler has cooled down

Parts commonly replaced

  • Overheat Thermostat
  • Circulation Pump
  • Internal Pipework (unblocking)

Related codes

E118

Your boiler has stopped working because the water pressure in the system has dropped too low and needs topping up.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually two braided silver hoses or blue levers) underneath the boiler.
  2. Open the valves slowly until you hear water entering the system.
  3. Watch the pressure gauge and close the valves tightly once the needle reaches 1.5 bar.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure relief valve
E125

Your boiler is struggling to move hot water around the system, which is usually caused by a blockage or a pump issue that is preventing the unit from cooling itself down.

High DIY-safe £150-350

What to check first

  1. Check that all radiator valves are fully open
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar on the gauge
  3. Gently bleed air from your radiators using a radiator key

Parts commonly replaced

  • Circulation pump
  • Plate heat exchanger
  • Main heat exchanger

Related codes

E128

Your boiler has lost its flame while running, which means it has safely shut down to prevent issues.

High DIY-safe £100-£350

What to check first

  1. Check if other gas appliances, like a hob, are working to confirm gas supply
  2. Ensure your pre-pay gas meter has sufficient credit
  3. Press and hold the Reset button for five seconds

Parts commonly replaced

  • Ignition electrode
  • Flame sensing electrode
  • Gas valve
  • Condensate trap

Related codes

E130

Your boiler has shut down because a sensor has detected that the exhaust gases are becoming too hot, which is a safety feature to prevent damage.

High Engineer only £100-£220

Parts commonly replaced

  • Flue NTC sensor
  • Main heat exchanger (cleaning or replacement)
  • Burner insulation

Related codes

E133

Your boiler has failed to light because it is not receiving enough gas or cannot detect the flame used to heat your water.

High DIY-safe £100-£350

What to check first

  1. Check if other gas appliances, like a cooker hob, are working to confirm your gas supply is active.
  2. If you have a prepayment meter, check that you have enough credit.
  3. Locate the white pipe beneath the boiler and ensure it hasn't frozen if the weather is very cold.
  4. Press the 'Reset' button for five seconds to see if the boiler restarts.

Parts commonly replaced

  • Gas Valve
  • Ignition Electrode
  • Printed Circuit Board (PCB)
  • Condensate Pipework

Related codes

Showing 51–60 of 68
E160

Your boiler has stopped working because the internal fan, which safely exhausts gases, is not spinning at the correct speed or has lost power.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Fan wiring harness
  • Main circuit board (PCB)

Related codes

E321

Your boiler has detected a problem with the sensor that monitors the temperature of your hot water, meaning your taps may not get as hot as they should or stay consistent.

Medium Engineer only £90-160

Parts commonly replaced

  • Hot water NTC temperature sensor
  • Wiring harness

Related codes

E384

Your boiler thinks a flame is present even when it should be off, causing it to shut down for safety.

High Engineer only £120-350

Parts commonly replaced

  • Flame sensing electrode
  • Ignition lead
  • Printed Circuit Board (PCB)

Related codes

Showing 61–68 of 68

3 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.