Remeha Avanta Plus 18s System Fault codes & diagnostics

21 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 2008-present
GC Number 41-288-11
Download the Remeha Avanta Plus 18s System manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 10 High 1 Medium 9 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-288-11 Avanta Plus 18S 2008–present

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 21 documented codes

Tap any card for details

8

Your boiler has temporarily paused because the water inside has become slightly hotter than it is supposed to be.

Low Engineer only £90-180

Parts commonly replaced

  • NTC temperature sensor
  • Automatic bypass valve
  • Circulating pump

Related codes

9

Your boiler has temporarily stopped working because a safety device wired into the system, such as a room thermostat or external timer, is signaling that something needs attention.

High Engineer only £90-180

Parts commonly replaced

  • External Thermostat
  • Wiring Centre
  • Time Clock

Related codes

d5

Your boiler has temporarily paused heating because the radiators are already as hot as the temperature you asked for, but it will automatically turn back on in a few minutes once it cools slightly.

Low Engineer only
d8

Your boiler has temporarily stopped because it detected that the water inside is getting hotter than the temperature you have set, likely due to poor circulation.

Medium Engineer only £120-250

Parts commonly replaced

  • Pump
  • Central heating filter
  • System diverter valve

Related codes

d9

Your boiler has switched itself off because the water inside is heating up too quickly or too unevenly, which often happens when water cannot circulate through your radiators properly.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Plate heat exchanger
  • Diverter valve

Related codes

é0

Your boiler is perfectly healthy and is simply waiting for a signal from your thermostat to turn on the heating or hot water.

Low DIY-safe

What to check first

  1. Check your room thermostat is set to a higher temperature than the current room temperature
  2. Ensure your heating timer or programmer is set to 'On'
  3. If the boiler still does not fire, check your hot water tap or cylinder settings
E01

Your boiler has tried to start up but cannot light the gas to create a flame.

High DIY-safe £100-280

What to check first

  1. Check that your gas supply is turned on at the meter.
  2. If you have a prepaid gas meter, check that you have remaining credit.
  3. Press the Reset button for two seconds to see if the boiler restarts.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Spark generator

Related codes

é1

Your boiler is currently going through its safety check phase before it attempts to light, which is a normal part of the startup process.

Low Engineer only

Parts commonly replaced

  • Air pressure switch
  • Fan
  • Printed Circuit Board

Related codes

é2

Your boiler has failed to light the flame needed to produce heat or hot water.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition transformer

Related codes

Showing 11–20 of 21
é4

Your boiler has tried to light itself several times but has failed, likely because there is no gas supply or the ignition part is dirty or broken.

High DIY-safe £100-280

What to check first

  1. Check if other gas appliances in your home, like a hob, are working to ensure gas is reaching the property.
  2. If you have a prepayment meter, check that you have remaining credit and the valve is open.
  3. Press the Reset button on the boiler control panel for one to two seconds.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB (Printed Circuit Board)

Related codes

é5

Your boiler is currently in a mandatory waiting period, meaning it is simply resting before it tries to restart itself.

Low Engineer only
é6

Your boiler is currently running its internal water circulation pump longer than expected after finishing a heating or hot water cycle, but this is usually just a system status notification rather than a breakdown.

Low Engineer only £80-150

Parts commonly replaced

  • Central heating pump
  • PCB

Related codes

é7

Your boiler has detected that there is not enough water inside the system to operate safely, or the internal pump is struggling to move the water around.

High DIY-safe £120-250

What to check first

  1. Check your system pressure gauge; if it is below 1 bar, top up the water using your boiler's filling loop until it reads between 1 and 1.5 bar.
  2. Ensure all radiator valves and your isolation valves underneath the boiler are fully open.
  3. Turn the boiler off at the fused spur for 30 seconds, then switch it back on to reset the fault.

Parts commonly replaced

  • Circulating pump
  • Pressure sensor
  • Water pressure switch

Related codes

é8

Your boiler has detected that the internal fan responsible for venting exhaust gases safely is either not spinning or communicating properly, so it has shut down to keep your home safe.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed Circuit Board (PCB)

Related codes

é10

Your boiler is simply running a standard three-minute safety and air-clearing cycle after a previous minor error before it attempts to turn back on.

Low DIY-safe

What to check first

  1. Wait for three minutes to see if the boiler automatically clears the cycle and fires up normally.
  2. If the boiler remains locked out, turn the power off and on again to reset the system.

Related codes

é11

Your boiler has detected that hot combustion gases are leaking into the internal casing, which is a serious safety concern that prevents the appliance from operating correctly.

Emergency Engineer only £180-350

Parts commonly replaced

  • Burner door seal
  • Heat exchanger seal
  • Flue seal

Related codes

é43

Your boiler has detected that some of its internal settings have drifted outside of their safe operating limits, and it has stopped working as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Main PCB

Related codes

é44

Your boiler has detected an internal software or settings error, which is preventing the system from starting up safely.

High Engineer only £120-250

Parts commonly replaced

  • Control board
  • Parameter key

Related codes

Showing 21–21 of 21
é45

Your boiler has lost its programmed settings and needs to be reconfigured by a professional to operate correctly.

High Engineer only £100-200

Parts commonly replaced

  • Control board

Related codes

1 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.