NocommunicationbetweenthemainPCBandtheuserinterface
Vaillant ecoFIT sustain 615 Fault codes & diagnostics
87 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 41-694-30 | ecoFIT sustain 615 VU 156/6-3 (H-GB) | 2018–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 87 documented codes
Tap any card for details
Fault:Flowtemperaturesensor
Fault:Returntemperaturesensor
Shortcircuit:Flowtemperaturesensor
Shortcircuit:Returntemperaturesensor
Shortcircuit:Cylindertemperature sensor
Shortcircuit:Temperaturesensorforthe domestichotwatercylinder
Safetyshutdown:Overheatingtemperat- urereached
Insufficient water pressure
Safetyshutdown:Temperaturespread toogreat(NTC1/NTC2)
Safetyshutdown:Temperaturerisetoo fast
Safetyshutdown:Fluegastemperature toohigh
Safetyshutdown:Faultinflamedetec- tion
Fault:Ignitionunsuccessfulwhenstarting up
Fault:Flameloss
Fanfrostprotectionfunctionactive:Fan speedoutsidethetolerancevalues
eBUSfault:Voltagetoolow
Fault:Gasvalveassemblycontrol
Fault:Gasvalveswitch-offcontrol
Fault:EEPROM
Fault:Electronics/sensor/analogue-to- digitalconverter
Fault:Electronicstemperaturetoohigh
ValuesentbackbyASICisincorrect (flamesignal)
Fault:Unstableflame(analogueinput)
Invalidproductcode(DSN)
Fault:Flow/returntemperaturesensor
Fault:Deviationinthewaterpressure sensor/returntemperaturesensor
Fault:Waterpressuresensornotcon- nectedorhasshort-circuited
Fault:Electricalprobleminthewater pressuresensor
Fault:Pressuresensor
Thesafetycut-outintheprimaryheat exchangerisdefective
Fault:Condensateorsmoke
InterruptiontoDHWoutletsensorat externalcontrol
Fault:Dryfire
Fault:Flow/returntemperaturesensor
Fault:Temperaturesensor
Fault:Underfloorheatingcontact
Fault:Electrodes
Fault:Gasvalveassembly
Fault:Pump
Shortcircuit:Cylindertemperature sensor
MainPCBself-testfailed
Heating mode: No requirement
Heating mode: Fan prerun
Heating mode: Pump prerun
Heating mode: Burner ignition
Heating mode: Burner on
Heating mode: Pump/fan overrun
Heating mode: Fan overrun
Heating mode: Pump overrun
Heating mode: Temporary shutdown after heating procedure
Domestic hot water mode: Requirement
Domestic hot water mode: Fan prerun
Domestic hot water mode: Burner ignition
DHW mode: Burner on
DHW mode: Pump/fan overrun
DHW mode: Fan overrun
DHW mode: Pump overrun
Domestic hot water mode: Requirement
Domestic hot water mode: Fan prerun
Domestic hot water mode: Pump prerun
Domestic hot water mode: Burner ignition
DHW mode: Burner on
DHW mode: Pump/fan overrun
DHW mode: Fan overrun
DHW mode: Pump overrun
Domestic hot water mode: Temporary shutdown of the burner
Room thermostat is blocking heating mode.
No heating demand: Summer mode, eBUS control, waiting period
Fan waiting time: Fan speed outside of the tolerance values
Forced fan operation until the pressure monitor is switched
Frost protection active
Underfloor heating contact open
Water pressure too high
Flue non-return flap closed
Frost protection mode (Comfort): Minimum load
Product in waiting period/operating block function due to water deficiency (flow/return spread too large)
Waiting period: Water deficiency in the circuit (flow/return spread too large)
Maintenance message: Check the water pressure
Product purging active
Maintenance: Demo mode
Automatic test programme: Return temperature sensor, heating demands blocked.
Automatic test programme: Water pressure sensor, heating demands blocked.
Automatictestprogramme:Returntemperaturesensor,heatingdemandsblocked.
Internalautomatictestprogrammes
Purgingthecombustionchamber,faninoperation
Product'sstandbymodeactivated
Avoid the next call-out bill
Monthly cover means no unexpected bills when your boiler breaks down.
Affiliate links. We may earn a commission at no extra cost to you.