What the manual says
Manufacturer manualAutomatic calibration of the combustion controller fault. Check gap between ionisation electrode and burner gauze assembly. Check allocation of gas type (parameter/coding address 82, gas train setting). Check flue system; remove flue gas recirculation if required. Press reset button R.
Engineer required
This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Avoid the next call-out bill
A cover plan would handle faults like Eb: no call-out fees, no surprise bills.
Affiliate links. We may earn a commission at no extra cost to you.
Related fault codes
All 89 fault codes on the Vitodens 200-W B2HB-35