dE on Viessmann Vitodens 200-W WB2C 26kW Combi

Your boiler has lost the room temperature reading for one of your heating zones, so it is heating that zone using outside weather readings instead, and it should still keep your home warm.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

What the manual says

Manufacturer manual

Control mode without room influence: Lead break, room temperature sensor, heating circuit 2 (with mixer)

From this model's manual
Verified against the Viessmann/Viessmann Vitodens 200 W Wb2c Service 5692857 installation & service manual.
Plain-English guidance below. Severity, DIY steps, costs and parts are our interpretation to help you act, not text from the manual.

DIY fix possible

Check that the room temperature sensor for the second heating circuit (usually a small wall-mounted unit near a thermostat) is plugged in securely and has no visible damage to its cable.Make sure the sensor is not blocked by furniture, curtains, or a radiator, and is not in direct sunlight or a draught.Reset the boiler using the reset button or the menu on the control panel, wait around 10 minutes, and check whether the code clears. If it returns, contact a Gas Safe registered engineer to test or replace the sensor.

Find a Gas Safe engineer
Search the official register →

Avoid the next call-out bill

A cover plan would handle faults like dE: no call-out fees, no surprise bills.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

Related fault codes

All 82 fault codes on the Vitodens 200-W WB2C 26kW Combi

Seeing a different code? Every code this model can display, in one place.

Related guides you might find useful