Block 11 on Atag Q 25S

Your boiler has paused the heating because the water is not circulating fast enough between the appliance and your radiators, causing a heat buildup inside the unit.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

Technical description

Maximum ΔT of flow and return sensor in central heating has repeatedly been exceeded. During the block normal operation of the hot water supply is possible. The pump continues to operate at minimum capacity during the block.

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.