Vaillant ecoTEC exclusive 627 VU 256/5-7 Fault codes & diagnostics

72 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Gas 2016-present
GC Number 41-694-02
Download the Vaillant ecoTEC exclusive 627 VU 256/5-7 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF
Other editions of this manual (the one above is 0020193966_04): 0020193966_02 (PDF) Manufacturers revise a model over the years. If your boiler is older than the manual above, an earlier edition may match it better.

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
7 Emergency 37 High 13 Medium 15 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-694-02 ecoTEC exclusive 627 VU 256/5-7 (H-GB) 2016–present
41-694-02 ecoTEC exclusive 627 VU 256/5-7 (H-GB) 2016–present

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 72 documented codes

Tap any card for details

F.00

Your boiler has stopped working because it has lost the electronic signal from the sensor that monitors water temperature.

High Engineer only £90-180

Parts commonly replaced

  • Flow NTC temperature sensor
  • Wiring harness

Related codes

F.01

Your boiler has temporarily stopped working because a temperature sensor inside has lost its electrical connection.

High Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.02

Your boiler has detected a faulty connection or sensor on the hot water system, meaning it cannot properly monitor your hot water temperature.

Medium Engineer only £90-180

Parts commonly replaced

  • DHW outlet sensor
  • NTC wiring harness

Related codes

F.03

Your boiler has temporarily lost connection to the hot water storage cylinder sensor, meaning it cannot properly monitor your hot water temperature.

Medium Engineer only £90-180

Parts commonly replaced

  • Cylinder temperature sensor
  • Sensor wiring harness

Related codes

F.10

Your boiler has detected a faulty temperature sensor or wiring issue, which has caused it to safely shut down to prevent overheating.

High Engineer only £120-£220

Parts commonly replaced

  • Flow temperature sensor (NTC)
  • Wiring harness

Related codes

F.11

Your boiler has stopped working because it is getting an incorrect temperature reading from one of its internal sensors.

High Engineer only £120-£220

Parts commonly replaced

  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.12

Your boiler has detected an electrical fault with the hot water temperature sensor, which means it cannot accurately measure how hot your water is getting.

Medium Engineer only £120-250

Parts commonly replaced

  • DHW temperature sensor
  • Wiring harness

Related codes

F.13

Your boiler is temporarily unable to accurately measure the temperature of your hot water cylinder due to a faulty sensor or loose wiring.

Medium Engineer only £120-250

Parts commonly replaced

  • Cylinder temperature sensor
  • Wiring harness

Related codes

F.20

Your boiler has safely shut down because it detected that the internal water temperature got too high.

High Engineer only £120-£250

Parts commonly replaced

  • Temperature sensor (NTC)
  • Wiring harness
  • Flow limiter

Related codes

F.22

Your boiler has temporarily stopped working because the water pressure inside the heating system has dropped too low.

High DIY-safe

What to check first

  1. Locate the filling loop underneath your boiler or check your user manual for system-specific repressurising instructions.
  2. Open the valves slowly to let mains water into the system until the pressure gauge on the front panel reads between 1.0 and 1.5 bar.
  3. Close the filling valves tightly and press the reset button on your Vaillant boiler.

Parts commonly replaced

  • Water pressure sensor
  • Pressure relief valve
  • Expansion vessel

Related codes

Showing 11–20 of 72
F.23

Your boiler has temporarily stopped working because water is not flowing through it properly, which can cause the system to get dangerously hot.

High Engineer only £150-350

Parts commonly replaced

  • Central heating pump
  • Flow/return NTC thermistor
  • Automatic air vent

Related codes

F.24

Your boiler has shut down because the internal water temperature rose too quickly, usually caused by trapped air, low system pressure, or a circulation issue.

High DIY-safe £100-£250

What to check first

  1. Check your boiler's pressure gauge to ensure it is between 1.0 and 1.5 bar.
  2. Top up the system pressure using the filling loop if it is too low.
  3. Bleed your radiators to release any trapped air in the system, then re-check the pressure.

Parts commonly replaced

  • Water pump
  • Flow sensor
  • Automatic air vent

Related codes

F.25

Your boiler has automatically shut down because the exhaust gases leaving the flue have become dangerously hot, or a safety sensor has been disconnected.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue gas safety cut-out sensor
  • Wiring harness
  • Main heat exchanger

Related codes

F.26

Your boiler has detected an issue with the valve that controls the gas supply, meaning it cannot safely ignite to provide heating or hot water.

Emergency Engineer only £150-£350

Parts commonly replaced

  • Gas valve stepper motor
  • Gas valve assembly
  • Wiring harness

Related codes

F.27

Your boiler has detected moisture or a false flame signal inside the unit and has safely locked itself out to prevent unsafe operation.

High Engineer only £150-£350

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Gas Valve
  • Flame Electrode

Related codes

F.28

Your boiler is failing to light because it cannot detect a successful flame or is not receiving enough gas to start up.

High Engineer only £100-£250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

F.29

Your boiler has tried to start up several times but failed to ignite, usually because the gas supply has been temporarily interrupted or the system cannot clear exhaust gases properly.

High Engineer only £120-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead
  • Circuit board (PCB)

Related codes

F.32

Your boiler has detected an issue with the internal fan that safely removes combustion gases, causing it to lock out for safety.

High Engineer only £150-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Main PCB

Related codes

F.33

Your boiler has temporarily stopped working because it has detected a blockage or issue with the airflow or flue system.

High Engineer only £150-300

Parts commonly replaced

  • Air pressure sensor
  • Pressure switch
  • Fan

Related codes

F.35

Your boiler has detected an issue with the airflow or the flue pipe that expels gases outside your home.

Emergency Engineer only £100-£250

Parts commonly replaced

  • Flue terminal
  • Air pressure switch
  • Fan assembly

Related codes

Showing 21–30 of 72
F.42

Your boiler has lost the digital signal from a key internal component, meaning it cannot safely recognise its own setup and has stopped working to protect itself.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Coding resistor / Wiring harness

Related codes

F.49

Your boiler is having trouble communicating with its external controllers or thermostats, preventing it from receiving instructions to heat your home.

High Engineer only £120-250

Parts commonly replaced

  • eBUS interface card
  • PCB
  • Wiring harness

Related codes

F.55

Your boiler has detected an issue with its internal carbon monoxide monitoring sensor, so it has safely shut down to protect you.

Emergency Engineer only £150-300

Parts commonly replaced

  • CO sensor
  • Main printed circuit board (PCB)
  • Wiring harness

Related codes

F.56

Your boiler has automatically shut down because it detected a dangerous level of combustion gases, which requires immediate attention from a qualified professional to ensure your safety.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue system
  • Gas valve
  • Burner seal
  • Air pressure switch

Related codes

F.57

Your boiler has temporarily stopped because it is running a specific sensor or calibration measuring test, which usually resolves itself or requires an engineer to complete the setup.

Low Engineer only
F.61

Your boiler has detected an issue with the internal gas valve control, meaning it cannot safely release gas to light the burner.

High Engineer only £200-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.62

Your boiler has detected an issue with the gas valve shutting down properly, meaning it is safely locking itself out to prevent any potential safety hazards.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.63

Your boiler's internal computer has encountered a memory error and cannot read the essential configuration data required to operate safely.

High Engineer only £300-600

Parts commonly replaced

  • Main PCB
  • Display PCB

Related codes

F.64

Your boiler has detected an internal electronic or sensor glitch and has safely shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Main printed circuit board (PCB)
  • Temperature sensors

Related codes

F.65

Your boiler has detected that the temperature of its internal electronic components is too high, so it has safely shut down to prevent permanent damage.

High Engineer only £150-350

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Main Electronic Control Unit

Related codes

Showing 31–40 of 72
F.67

Your boiler has detected an internal communication problem with its electronic control system, meaning it cannot safely confirm the flame is burning correctly.

High Engineer only £250-500

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame rectification sensor

Related codes

F.68

Your boiler is temporarily locking out because the flame inside is flickering or going out unexpectedly, meaning you currently have no heating or hot water.

High Engineer only £120-300

Parts commonly replaced

  • Flame sensor / Electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.70

Your boiler's computer memory has become corrupted, usually after a part has been replaced without being programmed correctly.

High Engineer only £90-180

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

F.71

Your boiler is temporarily unable to accurately measure the temperature of the water flowing through the system, so it has safely shut down to prevent overheating.

High Engineer only £120-220

Parts commonly replaced

  • Flow NTC sensor
  • Wiring harness

Related codes

F.72

Your boiler has detected a temperature mismatch between its internal water pipes, meaning it cannot safely regulate its heating.

High Engineer only £120-250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Wiring harness

Related codes

F.73

Your boiler's water pressure sensor is sending an incorrect reading, meaning the system cannot accurately check how much water is inside.

Medium Engineer only £100-200

Parts commonly replaced

  • Water pressure sensor
  • Pressure sensor wiring harness

Related codes

F.74

Your boiler is temporarily unable to read its internal water pressure correctly due to a sensor issue.

Medium Engineer only £100-£200

Parts commonly replaced

  • Water pressure sensor
  • Pressure sensor wiring harness

Related codes

F.75

Your boiler has detected a problem with the water pressure or the circulation pump, meaning it has safely shut down to prevent internal damage.

High DIY-safe £150-350

What to check first

  1. Check your boiler pressure gauge to see if it has dropped below 1 bar.
  2. If the pressure is low, use the filling loop to top the system up to approximately 1.0 to 1.5 bars.
  3. Reset the boiler using the reset button to see if it clears the fault.

Parts commonly replaced

  • Water pressure sensor
  • Central heating pump

Related codes

F.77

Your boiler has detected an issue with the way waste water or gases are leaving the system, causing it to lock out for safety.

High Engineer only £150-300

Parts commonly replaced

  • Condensate pump
  • Non-return valve
  • Wiring harness

Related codes

F.78

Your boiler has detected a communication issue with a hot water sensor, which temporarily affects its ability to properly regulate the temperature of your hot water.

Medium Engineer only £90-180

Parts commonly replaced

  • Domestic Hot Water Sensor
  • Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

Showing 41–50 of 72
F.80

Your boiler is having trouble reading the temperature of the water coming into its hot water storage tank, which means your stored hot water may not heat up properly.

Medium Engineer only £120-250

Parts commonly replaced

  • actoSTOR inlet temperature sensor
  • Wiring harness

Related codes

F.81

Your boiler is struggling to pump hot water to your cylinder, which means your stored hot water is not heating up properly.

High Engineer only £150-300

Parts commonly replaced

  • Cylinder charging pump
  • Pump cable harness
  • Main printed circuit board (PCB)

Related codes

F.82

Your boiler has detected an electrical fault with its internal corrosion-protection system, which means a qualified engineer needs to inspect the wiring.

Low Engineer only £90-180

Parts commonly replaced

  • External current anode
  • PCB
  • Wiring harness

Related codes

F.83

Your boiler has detected an abnormal temperature difference between its sensors, meaning it cannot safely regulate the heat.

High Engineer only £120-250

Parts commonly replaced

  • NTC thermistor
  • Flow sensor
  • Main printed circuit board

Related codes

F.84

Your boiler has detected a confusing difference in temperature readings between its internal sensors, so it has safely shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Flow / Return Thermistors
  • Main Printed Circuit Board (PCB)

Related codes

F.85

Your boiler has detected that its temperature sensors have been installed on the wrong pipes during recent maintenance or installation.

High Engineer only £90-180

Parts commonly replaced

  • Flow/Return NTC Thermistors
  • Wiring Harness

Related codes

F.90

Your boiler's main computer is having trouble communicating with its internal parts, meaning it has temporarily stopped working for safety.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

F.94

Your boiler has detected an issue with the internal water flow sensor and pressure system, meaning it has safely stopped working until the problem is checked.

High Engineer only £150-350

Parts commonly replaced

  • Vortex sensor
  • Differential pressure sensor
  • Main printed circuit board (PCB)

Related codes

S.34

Your boiler has noticed the temperature is very cold and has automatically turned itself on to prevent the internal pipes from freezing.

Low DIY-safe

What to check first

  1. No action is required; this is a normal safety function.
  2. The boiler will stop this mode automatically once the internal water temperature rises sufficiently.
  3. Ensure your external condensate pipe is not frozen if the weather is extremely cold.

Related codes

S.36

Your temperature settings are too low for the boiler to start heating, so the system is currently on standby.

Low DIY-safe £0-60

What to check first

  1. Check your wall thermostat or room controller
  2. Increase the temperature setting to above 20°C
  3. Ensure the thermostat is turned on and has working batteries

Parts commonly replaced

  • Thermostat batteries
  • Room thermostat

Related codes

Showing 51–60 of 72
S.37

Your boiler has temporarily stopped because it cannot get the internal fan spinning at the correct speed to safely clear exhaust gases.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

S.39

Your boiler has temporarily shut down because an external safety device, such as a condensate pump or an overheat sensor, has told it to stop running to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Condensate pump
  • External safety thermostat
  • External wiring loop

Related codes

S.40

Your boiler has temporarily reduced its heating performance to protect itself, meaning your radiators might not get as warm as usual while hot water continues to work normally.

Low DIY-safe

What to check first

  1. Wait to see if the boiler automatically exits protection mode once it finishes a current cycle or system check.
  2. Check that your heating controls and thermostat are not accidentally demanding more than the system can currently deliver.
  3. Restart the boiler using the reset button or power switch if the message persists for a long time.

Related codes

S.41

Your boiler has too much water in the system, which is causing high pressure and has triggered a safety shutdown to protect the components.

High DIY-safe £0-120

What to check first

  1. Check that the external filling loop valves are tightly closed
  2. Bleed water from one or more radiators into a container to reduce pressure
  3. Monitor the pressure gauge until it returns to between 1.0 and 1.5 bar
  4. Restart the boiler once the pressure is within the normal range

Parts commonly replaced

  • Filling loop valve
  • Expansion vessel
  • Pressure relief valve

Related codes

S.42

Your boiler has temporarily stopped working because it has detected an issue with the exhaust flue's safety flap or the water drainage pump.

High Engineer only £150-300

Parts commonly replaced

  • Condensate pump
  • VR40 multi-functional module
  • Flue non-return flap mechanism

Related codes

S.46

Your boiler is struggling to keep its flame steady while running at a very low power setting and has temporarily shut down to protect itself.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Flame sensing electrode
  • Ignition lead

Related codes

S.53

Your boiler has temporarily paused because the water is not flowing through the system fast enough, causing it to heat up too quickly.

Medium DIY-safe £100-350

What to check first

  1. Check that all radiator valves (TRVs) are fully open
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar on the display
  3. Check for any blocked magnetic filters or air locks in the radiators

Parts commonly replaced

  • Circulation pump
  • Main heat exchanger (cleaning/flush)
  • NTC thermistor

Related codes

S.54

Your boiler has temporarily paused itself because it detected that the water temperature is rising too quickly, suggesting there isn't enough water circulating through the system.

Medium DIY-safe £80-220

What to check first

  1. Check the pressure gauge on the boiler front or digital display and ensure it is between 1.0 and 1.5 bar.
  2. If pressure is low, use the filling loop underneath the boiler to top it up.
  3. Ensure all radiator valves and the boiler isolation valves are fully open.
  4. Bleed your radiators to remove any trapped air pockets.

Parts commonly replaced

  • External filling loop
  • Central heating pump
  • Main heat exchanger (flushing/cleaning)

Related codes

S.55

Your boiler is temporarily pausing its operation to allow its internal safety sensor to reset and calibrate.

Low Engineer only

Parts commonly replaced

  • CO sensor
  • Main printed circuit board (PCB)

Related codes

S.56

Your boiler has temporarily paused its operation because it detected high carbon monoxide levels in the exhaust gases, and it is waiting to ensure it is safe to restart.

Emergency Engineer only £100-300

Parts commonly replaced

  • Gas valve
  • Burner seal
  • Flue assembly
  • Air pressure sensor

Related codes

Showing 61–70 of 72
S.57

Your boiler is currently taking a short break to automatically re-calibrate its internal settings, during which it will temporarily pause heating and hot water production.

Medium DIY-safe

What to check first

  1. Wait up to 15 minutes for the boiler to complete its automatic calibration cycle.
  2. If the code persists, press the reset button (flame symbol with a cross).
  3. Monitor the boiler to see if it returns to normal operation after the waiting period.

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

S.58

Your boiler has detected unusual airflow patterns, likely caused by strong winds outside, and has temporarily limited its heat output to keep the system stable and quiet.

Low DIY-safe

What to check first

  1. Check for any external obstructions near the flue terminal outside
  2. Monitor the boiler to see if the code clears once wind conditions subside
  3. Perform a system reset if the boiler remains in a limited state after weather improves

Parts commonly replaced

  • Flue terminal
  • Fan assembly
  • Air pressure switch

Related codes

S.59

Your boiler is temporarily pausing because it cannot detect enough water flowing through the system to heat it safely.

Medium DIY-safe £100-250

What to check first

  1. Check that all radiator valves throughout your home are fully open
  2. Ensure your system pressure is at the correct level, typically between 1.0 and 1.5 bar
  3. Check for any blockages in your external magnetic system filter if one is fitted

Parts commonly replaced

  • Central heating pump
  • Flow sensor
  • System pressure gauge

Related codes

S.76

Your boiler has detected that the water level inside the heating system has dropped too low and needs to be topped up to function correctly.

Medium DIY-safe

What to check first

  1. Locate the filling loop (a flexible silver hose) connecting your cold mains pipe to your heating pipework.
  2. Open the valves on both ends of the filling loop to allow water to enter the system.
  3. Watch the pressure gauge on the front of the boiler until the needle reaches the green zone (usually between 1.0 and 1.5 bar), then close both valves tightly.

Parts commonly replaced

  • Pressure relief valve
  • Expansion vessel

Related codes

S.86

Your boiler is displaying a routine reminder message to check the internal water flow sensor, but your heating and hot water should still be working normally.

Low Engineer only £90-180

Parts commonly replaced

  • Vortex sensor
  • Flow sensor harness

Related codes

S.88

Your boiler is currently running its automatic air-removal cycle, which is a normal process usually triggered after being refilled, serviced, or restarted.

Low DIY-safe

What to check first

  1. Wait for the purging programme to finish automatically, which usually takes a few minutes.
  2. Check your system pressure gauge to ensure it is between 1.0 and 1.5 bar.
  3. Bleed your radiators if you notice trapped air in the heating system.

Related codes

S.92

Your boiler is running an automatic internal test to check the flow of water through the system.

Low DIY-safe

What to check first

  1. Wait a few minutes to see if the boiler completes the test and returns to normal operation.
  2. Check that all radiator valves are fully open to allow proper water circulation.

Related codes

S.96

Your boiler is performing a self-diagnostic check on its internal temperature sensors and has temporarily paused heating until it confirms everything is working correctly.

Low DIY-safe £0-120

What to check first

  1. Wait up to 15 minutes for the automated test to complete
  2. Switch the boiler off and back on at the fused spur switch to trigger a restart
  3. Ensure all radiator valves are open to allow for proper water circulation

Parts commonly replaced

  • Return NTC thermistor
  • Flow NTC thermistor

Related codes

S.97

Your boiler is currently performing a self-test of its internal pressure sensor and has temporarily paused heating until it finishes.

Low DIY-safe £0-180

What to check first

  1. Wait up to 15 minutes for the automated test to complete
  2. Ensure your system water pressure is within the green zone on the digital display
  3. If the code persists, try restarting the boiler using the power button

Parts commonly replaced

  • Water pressure sensor
  • Expansion vessel

Related codes

Showing 71–72 of 72
S.98

Your boiler is temporarily running a self-test on its internal temperature sensors and pausing your heating until the check is finished.

Low Engineer only

Parts commonly replaced

  • Flow/return temperature sensor
  • NTC sensor

Related codes