No light on Worcester Bosch Greenstar 12Ri

Your boiler appears to have no power and the display is completely dead, meaning it cannot provide any heating or hot water.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

What the manual says

Manufacturer manual

No power at control board. Possible solutions/checks: Permanent mains supply to boiler, Boiler mains switch ON, Fuse F1 - 2A Slow blow, Fuse F2 - 1.25A Anti-surge, Transformer (both coils below 100Ω. Otherwise replace control board.

From this model's manual
Verified against the Worcester Bosch Greenstar 12ri installation & service manual, page 48.
Plain-English guidance below. Severity, DIY steps, costs and parts are our interpretation to help you act, not text from the manual.

What causes this fault?

This fault occurs when the electrical circuit inside the boiler is interrupted, preventing power from reaching the internal components. The most common reason is a blown internal fuse or a failure within the transformer, which acts as the heart of the boiler's electrical system. In some cases, a power surge or a short circuit on the main control board can cause the unit to shut down completely to prevent further damage.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Avoid the next call-out bill

A cover plan would handle faults like No light: no call-out fees, no surprise bills.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

Related guides you might find useful