Technical description
No power at control board. Possible solutions/checks: Permanent mains supply to boiler, Boiler mains switch ON, Fuse F1 - 2A Slow blow, Fuse F2 - 1.25A Anti-surge, Transformer (both coils below 100Ω. Otherwise replace control board.
What causes this fault?
This fault occurs when the electrical circuit inside the boiler is interrupted, preventing power from reaching the internal components. The most common reason is a blown internal fuse or a failure within the transformer, which acts as the heart of the boiler's electrical system. In some cases, a power surge or a short circuit on the main control board can cause the unit to shut down completely to prevent further damage.
Engineer required
This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.