Worcester Bosch Greenstar 30HE Fault codes & diagnostics

21 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural GasLPG 30 kW 2003-2007 Discontinued
GC Number 47-311-56

Replaced by: Greenstar 30i

The Greenstar 30HE range comes in 2 types

Pick the one you have. The fault codes, GC numbers and manual differ by type.

Each model has its own manual A family spans several manuals, one per model or generation. Pick your model above and its page has the manual its fault codes were read from.

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 17 High 1 Medium 2 Low

All 21 documented codes

Tap any card for details

5.2

Your boiler has detected a problem with its electronic ignition system, meaning it cannot process the command to start the flame safely.

High Engineer only £250-£450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • GFA Ignition Controller

Related codes

9.3

Your boiler’s internal computer has encountered a memory error and cannot safely operate the heater.

High Engineer only £280-450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Code Plug

Related codes

A1

Your boiler has detected that there is not enough water circulating through the system to operate safely.

High DIY-safe £60-120 Shared across the Greenstar Zwbr range

What to check first

  1. Check your boiler's pressure gauge to see if it is below 1 bar
  2. Locate the filling loop (usually silver braided hoses under the boiler)
  3. Slowly open the valves until the pressure reaches 1.5 bar, then close them tightly

Parts commonly replaced

  • Filling loop
  • Expansion vessel recharge
  • Internal pump

Related codes

A5

Your boiler's temperature sensor responsible for monitoring stored hot water has developed a fault, preventing it from reading the temperature correctly.

High Engineer only £90-160 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • NTC thermistor sensor
  • Wiring harness connector

Related codes

A7

Your boiler is struggling to accurately measure the temperature of your hot water, which usually means your taps will only run cold or slightly warm.

High Engineer only £90-160 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Sensor
  • Connecting Wiring Harness

Related codes

A8

Your boiler's internal computer has lost its connection with the main control board, preventing the system from operating.

High Engineer only £150-£450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Wiring harness
  • Heatronic PCB
  • User Interface Control board

Related codes

AC

Your boiler's main control computer is unable to communicate with its internal plug-in components, meaning the system cannot safely start up.

High Engineer only £180-450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • PCB (Printed Circuit Board)
  • Heatronic Module
  • Internal Wiring Harness

Related codes

Ad

Your boiler is unable to detect the temperature sensor for your hot water tank, which means it doesn't know when to heat your water.

Medium Engineer only £90-160 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Cylinder NTC sensor
  • Sensor wiring harness

Related codes

b1

Your boiler's internal computer is having trouble communicating with its identity chip, meaning it doesn't recognize its own settings.

High Engineer only £120-450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Code plug
  • Printed Circuit Board (PCB)
C1

Your boiler has stopped working because the internal fan, which clears exhaust gases, isn't spinning fast enough to operate safely.

High Engineer only £200-£450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Venturi tube

Related codes

Showing 11–20 of 21
C6

Your boiler's fan is spinning faster than it should, which has caused the system to shut down for safety purposes.

High Engineer only £220-£450 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)

Related codes

d3

Your boiler has lost the signal from an external control, such as your room thermostat or programmer, preventing it from firing up.

High Engineer only £90-180 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • External wiring connection
  • External thermostat
  • Boiler control board

Related codes

E2

Your boiler has detected a faulty internal temperature sensor, which means it cannot accurately measure how hot the water is and has stopped running for safety.

High Engineer only £90-160 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Central Heating Flow NTC Sensor
  • Wiring Harness Connection

Related codes

E9

Your boiler has switched itself off because it has detected that it is getting far too hot inside.

High DIY-safe £100-£350 Shared across the Greenstar Zwbr range

What to check first

  1. Check that the boiler pressure is between 1 and 1.5 bar on the needle gauge.
  2. Ensure all radiator valves are fully open to allow water to flow.
  3. Press the 'Reset' button on the front of the boiler once the system has cooled down.

Parts commonly replaced

  • Overheat Thermostat
  • Central Heating Pump
  • Heat Exchanger
EA

Your boiler is failing to light the gas or isn't detecting that the flame has started, causing the system to shut down for safety.

High DIY-safe £100-£350 Shared across the Greenstar Zwbr range

What to check first

  1. Check if other gas appliances in your home, like a hob, are working to confirm your gas supply is active.
  2. If it is freezing outside, check that your external condensate pipe hasn't frozen and blocked.
  3. Press and hold the reset button for five seconds to see if the boiler restarts.

Parts commonly replaced

  • Ignition Electrode
  • Flame Sensor (Ionisation Probe)
  • Gas Valve
  • PCB

Related codes

F0

Your boiler's internal computer has encountered a communication error or software glitch that is preventing it from running safely.

High DIY-safe £280-450 Shared across the Greenstar Zwbr range

What to check first

  1. Press and hold the reset button for five seconds
  2. Wait for the boiler to complete its restart sequence
  3. If the code persists, turn the main power switch to the boiler off and back on again

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F7

Your boiler is still sensing a flame even when it should be turned off, which is a safety conflict that prevents the system from starting.

High Engineer only £120-£350 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Ionisation Probe
  • Flame Sensing Electrode
  • Printed Circuit Board (PCB)

Related codes

FA

Your boiler is still detecting a flame even after it should have turned off, which is a safety concern that prevents the system from running.

Emergency Engineer only £120-350 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Gas valve
  • Ionisation probe
  • Control board (PCB)

Related codes

FC

Your boiler's main control board is having trouble communicating with the display panel, meaning the system cannot correctly send or receive instructions.

High Engineer only £180-350 Shared across the Greenstar Zwbr range

Parts commonly replaced

  • Main PCB
  • Display Interface Board
  • Wiring Harness

Related codes

Fd

Your boiler has been put into a temporary reset mode because the button was held down too long or pressed accidentally.

Low DIY-safe Shared across the Greenstar Zwbr range

What to check first

  1. Press the reset button firmly once and release it immediately
  2. Wait up to 30 seconds for the display to return to a normal temperature reading
  3. If the code persists, switch the boiler's power off and back on at the fused spur switch

Related codes

Showing 21–21 of 21

4 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.