What the manual says
Manufacturer manualWaiting cycle: temperature differential between heating fl ow and return is too high. If ∆T > 30, forcing to Pmin
From this model's manual
Verified against the Heatline Caprizplus 24a installation & service manual, page 26.
DIY fix possible
Check that all radiator valves (TRVs) are fully openEnsure the boiler pressure is between 1.0 and 1.5 bar on the gaugeBleed all radiators to remove trapped air bubbles