High
E 19 on Ideal Imax W

Your boiler is shutting down because the water returning to it is too hot, typically indicating a problem with the internal circulation or the system's sensors.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Return temperature too high

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Related fault codes

Related guides you might find useful