What the manual says
Manufacturer manualRegulates as if the outside temperature were 0 °C. Cause: Communication interruption, outside temperature sensor RF: Outside temperature sensor RF, KM-BUS to wireless base station, wireless base station or wireless repeater faulty or defective.
DIY fix possible
Check that the boiler's wireless base station (the small box connected to the boiler) has power and that its indicator light is on.Check the batteries in the wireless outside temperature sensor and replace them if they are low, following the manufacturer's instructions.Make sure the outside sensor is mounted on a shaded north or north-facing wall, away from windows, vents and direct sunlight, and that nothing is blocking the signal path between the sensor and the base station.Switch the boiler off at the control panel for a few minutes, then switch it back on so it re-establishes communication with the sensor.If the code returns, contact a Gas Safe registered engineer to test the wireless signal and replace the sensor or base station if needed.