What the manual says
Manufacturer manualFault E3. Automatic calibration of the combustion controller. Measure: Ensure adequate heat transfer. Press reset button R.
DIY fix possible
Check the pressure gauge on the front of the boiler when the system is cold; it should read between 1.0 and 1.5 bar. If it is low, top it up using the filling loop as shown in the manual, then close the loop valves.Bleed any radiators that are cold at the top or feel cooler than the rest, using a radiator key, and check the pressure again afterwards.Press the reset button marked R on the boiler control panel and let the boiler run its calibration without interruption for a few minutes. If the code returns, stop and call a Gas Safe registered engineer.
Avoid the next call-out bill