Potterton Suprima HE Fault codes & diagnostics

23 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Regular Natural Gas 8.8-23.4 kW 2001-2011 Discontinued

Replaced by: Potterton Promax

The Suprima HE range comes in 9 types

Pick the one you have. The fault codes, GC numbers and manual differ by type.

Each model has its own manual A family spans several manuals, one per model or generation. Pick your model above and its page has the manual its fault codes were read from.

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
2 Emergency 21 High

All 23 documented codes

Tap any card for details

24

Your boiler has stopped working because it cannot maintain a stable flame or there is a blockage in the pipe that drains away moisture produced during operation.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • PCB
  • Flame sensing electrode
  • Condensate trap

Related codes

25

Your boiler has detected that it is getting too hot and has automatically shut down to prevent damage or dangerous overheating.

Emergency Engineer only £150-300 Shared across the Suprima range

Parts commonly replaced

  • Safety Thermostat
  • Pump
  • PCB
  • Diverter Valve

Related codes

26

Your boiler is struggling to clear exhaust fumes or draw in fresh air, so it has safely shut down to prevent any risk of harmful gases escaping.

High Engineer only £180-350 Shared across the Suprima range

Parts commonly replaced

  • Fan assembly
  • Air pressure switch
  • Venturi
27

Your boiler is struggling to circulate water, most likely because the pressure inside your system has dropped too low to operate safely.

High DIY-safe £90-250 Shared across the Suprima range

What to check first

  1. Locate the external filling loop, usually two valves with a flexible silver hose between them near the boiler or pipes.
  2. Open the valves slowly to allow water into the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close both valves firmly and check the boiler display to see if the fault clears.

Parts commonly replaced

  • Central heating pump
  • Pressure relief valve
  • Expansion vessel

Related codes

28

Your boiler is struggling to accurately measure the temperature of the water it is heating, so it has stopped working to prevent potential overheating.

High Engineer only £120-200 Shared across the Suprima range

Parts commonly replaced

  • Domestic Hot Water (DHW) Sensor
  • Wiring Harness
29

Your boiler has lost the ability to accurately measure the temperature of the water being sent to your radiators, so it has safely shut down to prevent overheating.

High Engineer only £120-220 Shared across the Suprima range

Parts commonly replaced

  • Central heating NTC thermistor
  • Wiring harness

Related codes

APS Cycling LOCKOUT

Your boiler has detected an issue with its internal ventilation system four times in a row, causing it to shut down for safety reasons.

High Engineer only £150-250 Shared across the Suprima range

Parts commonly replaced

  • Air Pressure Switch
  • Venturi
  • Fan assembly

Related codes

APS Stuck Fault

Your boiler has detected that a safety sensor is stuck in the 'on' position before the fan has even started, so it has stopped working as a precaution.

High Engineer only £150-250 Shared across the Suprima range

Parts commonly replaced

  • Air Pressure Switch
  • Venturi
  • Fan Assembly

Related codes

Casting Thermistor Fault

Your boiler has lost the ability to accurately measure the temperature of its internal heat exchanger, so it has safely shut down to prevent overheating.

High Engineer only £150-250 Shared across the Suprima range

Parts commonly replaced

  • Casting thermistor sensor
  • Wiring harness

Related codes

Circulation

Your boiler has detected that hot water is not flowing through your heating system correctly, which is causing it to shut down to prevent overheating.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Circulation pump
  • Flow switch
  • Central heating filter
Showing 11–20 of 23
Circulation LOCKOUT

Your boiler has detected that hot water isn't moving around your radiators or pipes properly and has shut itself down to prevent overheating.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Central heating pump
  • System filter
  • Diverter valve
  • PCB

Related codes

Electrical Supply Fault

Your boiler is failing to detect the necessary electrical power to operate, which may be caused by a loose wire or an issue with your heating controls.

High Engineer only £120-250 Shared across the Suprima range

Parts commonly replaced

  • PCB
  • Wiring harness
  • External programmer

Related codes

False Flame Fault

Your boiler has detected a flame when it shouldn't be there, which means it has safely shut down to prevent a dangerous situation.

Emergency Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Gas Valve

Related codes

Flow Thermistor Fault

Your boiler has stopped working because it cannot accurately measure the temperature of the water flowing through the system.

High Engineer only £120-220 Shared across the Suprima range

Parts commonly replaced

  • Flow Thermistor/NTC Sensor
  • Wiring Harness

Related codes

Ignition LOCKOUT

Your boiler has stopped working because it failed to light the flame after several attempts, so it has shut itself down for safety.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB (Printed Circuit Board)

Related codes

Lockout

Your boiler has failed to start after several attempts and is now safely preventing itself from turning on to protect your home.

High Engineer only £120-250 Shared across the Suprima range

Parts commonly replaced

  • PCB
  • Ignition Lead
  • Spark Generator

Related codes

No Switched Live

Your boiler has completely lost the electrical signal it needs to start running, meaning it is currently unable to provide any heating or hot water.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Control PCB
  • Transformer
  • Internal Fuse
Overheat

Your boiler has automatically turned itself off because it has become dangerously hot and needs to cool down before it can be used again.

High Engineer only £150-350 Shared across the Suprima range

Parts commonly replaced

  • Pump
  • PCB
  • Thermostat
  • Diverter valve

Related codes

Overheat condition

Your boiler has switched itself off because it has become too hot and needs a manual reset to restart.

High DIY-safe £100-£250 Shared across the Suprima range

What to check first

  1. Locate the reset button on the control panel at the bottom of the boiler.
  2. Press and hold the reset button for at least 2 seconds.
  3. Wait for the flashing red light to turn green or stop flashing.
  4. Ensure your radiator valves are open and the system is pressurized.

Parts commonly replaced

  • Circulation pump
  • Overheat thermostat
  • Thermistor
Overheat LOCKOUT

Your boiler has detected that it has become too hot and has automatically shut itself down to prevent internal damage.

High Engineer only £120-250 Shared across the Suprima range

Parts commonly replaced

  • Overheat thermostat
  • Central heating pump
  • PCB
  • Diverter valve

Related codes

Showing 21–23 of 23
Overheat Thermostat

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

High Engineer only £120-250 Shared across the Suprima range

Parts commonly replaced

  • Overheat thermostat
  • Central heating pump
  • PCB

Related codes

PCB Fault

Your boiler's internal computer has stopped working correctly and is no longer able to safely manage the heating system.

High Engineer only £250-400 Shared across the Suprima range

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

THERMISTOR

Your boiler has detected an issue with the sensor that monitors its temperature, which prevents it from heating your home or water safely.

High Engineer only £150-250 Shared across the Suprima range

Parts commonly replaced

  • NTC Thermistor
  • Wiring Harness

Related codes

2 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.