Glow-worm 30ci Plus Fault codes & diagnostics

22 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural GasLPG 30 kW 2002 onwards Discontinued
GC Number 47-047-22

Replaced by: Flexicom cx

Download the Glow-worm 30ci Plus manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 18 High 3 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-047-22 30ci Plus 2002–present

All 22 documented codes

Tap any card for details

0.5bar

Your boiler has lost water pressure and has shut down to prevent damage, meaning you currently have no heating or hot water.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually two blue or black levers) underneath the boiler.
  2. Slowly open both levers until you hear water flowing and the pressure gauge rises.
  3. Close both levers tightly once the gauge reaches 1.5 bar.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure sensor

Related codes

01

Your boiler has stopped working because it cannot light the gas burner to provide heating or hot water, usually because the gas supply is interrupted or the ignition spark has failed.

High DIY-safe £120-350

What to check first

  1. Check if your gas meter has credit or if other gas appliances in your home are working.
  2. Ensure the blue gas isolation valve under the boiler is in the 'open' position (aligned with the pipe).
  3. Press the 'Reset' button (indicated by a flame with a line through it) and hold for one second.

Parts commonly replaced

  • Ignition electrode
  • Lead assembly
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

02

Your boiler has stopped working because the fan isn't starting up to safely clear waste gases from the system.

High Engineer only £120-£350

Parts commonly replaced

  • Fan unit
  • Air pressure switch
  • Main PCB

Related codes

2.7bar

Your boiler has too much water inside it, causing the pressure to rise to an unsafe level.

Medium DIY-safe £60-180

What to check first

  1. Check that the filling loop valves are tightly closed
  2. Bleed water from a radiator using a bleed key to reduce pressure
  3. Monitor the pressure gauge to ensure it returns to between 1.0 and 1.5 bar
  4. Reset the boiler once the pressure is within the normal range

Parts commonly replaced

  • Filling loop valve
  • Expansion vessel
  • Pressure relief valve (PRV)

Related codes

03

Your boiler has detected an issue with how it moves air and waste gases through the system, causing it to shut down for safety.

High Engineer only £100-£350

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Flue seals
  • Venture tube

Related codes

04

Your boiler has stopped working because it cannot light the gas needed to provide heating and hot water.

High DIY-safe £100-350

What to check first

  1. Check if your gas supply is turned on at the meter
  2. Check if other gas appliances, like a hob, are working correctly
  3. Press the reset button (indicated by a flame with a line through it) for five seconds

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

05

Your boiler has shut down because it has detected it is getting too hot, usually due to a lack of water flow or a circulation blockage.

High DIY-safe £120-350

What to check first

  1. Check if your radiator valves are open to ensure water can circulate.
  2. Check the boiler pressure gauge and top it up to 1.5 bar if it is low.
  3. Gently press the reset button on the front of the boiler.

Parts commonly replaced

  • Circulation pump
  • Overheat thermostat (Limit stat)
  • Main heat exchanger

Related codes

06

Your boiler has stopped working because a sensor that measures the temperature of the water leaving the unit has failed or has a poor connection.

High Engineer only £90-160

Parts commonly replaced

  • Central heating flow NTC thermistor
  • Wiring harness / Connector

Related codes

07

Your boiler is struggling to accurately measure the temperature of your hot water due to a faulty internal sensor.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC thermistor
  • Connecting wiring harness

Related codes

08

Your boiler has detected a problem with the sensor that monitors the temperature of its internal hot water store.

Medium Engineer only £90-180

Parts commonly replaced

  • Micro-accumulation NTC sensor
  • Wiring harness

Related codes

Showing 11–20 of 22
09

Your boiler has lost the ability to monitor its own water pressure, meaning it has shut down to prevent damage even if there is enough water inside.

High Engineer only £130-190

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness connector

Related codes

10

Your boiler has stopped working because a sensor that monitors the temperature of the water returning from your radiators has developed a fault.

High Engineer only £90-160

Parts commonly replaced

  • Central Heating Return NTC Sensor
  • Connecting Wiring Loom

Related codes

11

Your boiler has lost the connection between its control panel and its internal computer, meaning it cannot receive any instructions to turn on.

High Engineer only £150-250

Parts commonly replaced

  • MMI connection lead
  • User interface display board
  • Main printed circuit board (PCB)

Related codes

12

Your boiler is having trouble communicating with the control panel or your thermostat, meaning it cannot receive your instructions to turn on.

High Engineer only £120-280

Parts commonly replaced

  • User Interface PCB
  • Wiring Harness
  • External Thermostat

Related codes

13

Your boiler's internal computer has developed a fault and can no longer control the heating system safely.

High Engineer only £280-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

14

Your boiler has reached an unsafe temperature and has shut itself down to prevent damage or overheating.

High DIY-safe £120-350

What to check first

  1. Check that all radiator valves are fully open to allow water to circulate.
  2. Ensure the boiler pressure gauge is between 1.0 and 1.5 bar.
  3. Reset the boiler using the power button or reset switch and see if the fault clears.

Parts commonly replaced

  • Circulation pump
  • Overheat thermostat
  • Main heat exchanger (flushing/cleaning)

Related codes

15

Your boiler is unable to control the gas flow properly, which is preventing it from lighting to provide heating or hot water.

High Engineer only £180-320

Parts commonly replaced

  • Gas valve
  • Wiring harness
  • Main PCB

Related codes

16

Your boiler has detected a problem with how gas flows into the unit, meaning it has shut down for safety to prevent a gas-related issue.

Emergency Engineer only £180-350

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

17

Your boiler has stopped working because the electrical power coming from your mains supply has dropped too low for it to run safely.

High Engineer only £100-280

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • External Voltage Regulator

Related codes

18

Your boiler's control panel and its main computer are having trouble communicating with each other, meaning you cannot change settings or see the boiler's status correctly.

High Engineer only £180-350

Parts commonly replaced

  • User Interface (Display PCB)
  • Main Printed Circuit Board (PCB)
  • Internal Wiring Harness
Showing 21–22 of 22
19

Your boiler has detected that a temperature sensor has lost physical contact with the internal pipework, meaning it can no longer monitor heat levels correctly.

High Engineer only £90-160

Parts commonly replaced

  • Central Heating NTC Sensor
  • Sensor retaining clip
  • Wiring harness connector

Related codes

20

Your boiler's internal control screen is unable to talk to the main computer, which prevents the heating from turning on.

High Engineer only £180-350

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Internal User Interface Display

Related codes