S.53 on Glow-worm Ultracom 2 SXI

Your boiler has temporarily paused because the water leaving the unit is getting much hotter than the water returning, suggesting a circulation problem.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

What the manual says

Manufacturer manual

waiting time: temperature difference flow - return sensor too high (Check thermistor fit)

From this model's manual
Verified against the Glow Worm Ultracom 2 Sxi installation & service manual, page 55.
Plain-English guidance below. Severity, DIY steps, costs and parts are our interpretation to help you act, not text from the manual.

What causes this fault?

This fault occurs when the boiler detects that heat isn't being moved away from the unit quickly enough, causing the outgoing water to become significantly hotter than the returning water. The most common reasons are a failing internal pump that can't push the water around your radiators, or a buildup of sludge and debris that is restricting the flow within the system.

This issue often surfaces in autumn when the heating is turned back on for the first time, as pump components can seize or debris can settle during the summer months.

DIY fix possible

Check that all radiator valves are fully openEnsure the boiler pressure is between 1.0 and 1.5 barBleed your radiators to remove any trapped air

Find a Gas Safe engineer
Search the official register →

Avoid the next call-out bill

A cover plan would handle faults like S.53: no call-out fees, no surprise bills.