High Lockout
F.71 on Vaillant ecoTEC exclusive

Your boiler has detected that a temperature sensor is sending a stuck or frozen reading, preventing it from heating your home or water safely.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Fault:Flowsensor Flowtemperaturesensorsignallingconstantvalue: – Flowtemperaturesensorincorrectlypositionedatflowpipe – Flowtemperaturesensordefective

What causes this fault?

This fault occurs when the boiler's internal computer notices that the flow temperature sensor is sending exactly the same temperature reading for too long, even while the burner is firing. The most common reason is that the sensor has physically failed or developed a high resistance, meaning it can no longer detect the actual rise in heat. It can also be caused by a loose connection or damaged wiring preventing the sensor from communicating correctly with the main control board.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →