Vaillant ecoTEC exclusive 832 Fault codes & diagnostics

31 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

GC Number 47-044-37
Download the Vaillant ecoTEC exclusive 832 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 29 High 1 Low

All 31 documented codes

Tap any card for details

con

Your boiler's internal computer brain is unable to talk to the front display panel, meaning the system cannot receive instructions to provide heating or hot water.

High Engineer only £180-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Display Interface
  • Internal Wiring Loom

Related codes

F.0

Your boiler has lost its connection to the sensor that measures the water temperature as it leaves the unit, meaning it cannot safely judge how much heat to provide.

High Engineer only £90-180

Parts commonly replaced

  • Flow Temperature Sensor (NTC)
  • Wiring Harness
  • Main PCB

Related codes

F.1

Your boiler has stopped working because it cannot communicate with the sensor that monitors the temperature of the water returning to the unit.

High Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor (NTC)
  • Wiring loom
  • Main PCB

Related codes

F.10

Your boiler has stopped working because it thinks the main water temperature sensor is broken or there is a problem with its internal wiring.

High Engineer only £90-180

Parts commonly replaced

  • NTC flow temperature sensor
  • Wiring harness

Related codes

F.11

Your boiler has stopped working because it cannot correctly read the temperature of the water returning to the unit due to an electrical connection issue.

High Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.13

Your boiler has detected an electrical fault with the internal sensor that monitors the temperature of its hot water storage tank.

High Engineer only £120-£200

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring loom
  • Sensor connection plug

Related codes

F.20

Your boiler has shut down because it has detected an unsafe increase in internal temperature, likely caused by a sensor fault or an issue with water flow.

High Engineer only £120-£280

Parts commonly replaced

  • NTC Temperature Sensor
  • Overheat Thermostat
  • Circulation Pump

Related codes

F.22

Your boiler has stopped working because the water pressure is too low for it to operate safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) underneath or near the boiler.
  2. Slowly open the valve(s) until you hear water entering the system.
  3. Watch the pressure gauge and close the valves once the needle reaches between 1.0 and 1.5 bar.

Parts commonly replaced

  • Filling loop valves
  • Expansion vessel
  • Pressure sensor

Related codes

F.23

Your boiler has detected that water isn't moving through the system fast enough, causing a large temperature difference that has triggered a safety shutdown.

High DIY-safe £180-450

What to check first

  1. Check that all radiator valves are fully open
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar
  3. Restart the boiler using the reset button

Parts commonly replaced

  • Circulation pump
  • NTC Temperature Sensors
  • Main Heat Exchanger (Flushing)

Related codes

F.24

Your boiler is overheating too quickly because water isn't flowing through the system correctly, often due to low pressure or trapped air.

High DIY-safe £100-£350

What to check first

  1. Check the pressure gauge and top up the water to 1.5 bar if it is too low
  2. Bleed any air from your radiators using a radiator key
  3. Ensure all radiator valves and isolation valves are fully open

Parts commonly replaced

  • Circulation pump
  • Pump capacitor
  • Pressure sensor

Related codes

Showing 11–20 of 31
F.25

Your boiler has detected an internal electrical connection issue that is preventing it from running safely.

High Engineer only £120-£350

Parts commonly replaced

  • Wiring harness
  • Main PCB
  • Flue gas thermostat

Related codes

F.27

Your boiler has detected a flame when there shouldn't be one, which has caused the system to shut down for safety.

High Engineer only £150-350

Parts commonly replaced

  • Flame sensing electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.28

Your boiler is failing to light the gas flame, meaning it cannot provide heat or hot water.

High DIY-safe £90-350

What to check first

  1. Check if your gas emergency control valve (usually by the meter) is in the 'on' position.
  2. If using a prepayment meter, ensure you have sufficient credit and the valve hasn't locked.
  3. Try resetting the boiler by pressing the flame symbol with a cross through it for five seconds.

Parts commonly replaced

  • Ignition lead and electrodes
  • Gas valve
  • Spark generator
  • Printed Circuit Board (PCB)

Related codes

F.29

Your boiler has lost its flame while running and cannot manage to restart itself, likely due to a temporary interruption in the gas supply or a component failure.

High DIY-safe £100-350

What to check first

  1. Check if other gas appliances, like a hob, are working to ensure gas is reaching the property.
  2. If you have a pre-payment meter, check that you have sufficient credit.
  3. Press the reset button (indicated by a flame symbol with a cross) for one second to see if the boiler restarts.

Parts commonly replaced

  • Ignition lead
  • Ignition electrodes
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.32

Your boiler has detected a problem with the fan that safely pushes waste gases out of your home, causing the system to shut down for safety.

High Engineer only £250-£480

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Main PCB (Printed Circuit Board)
F.49

There is a communication error between your boiler and its controls, often caused by an electrical wiring fault or a heavy load on the internal data connection.

High Engineer only £90-180

Parts commonly replaced

  • eBUS wiring
  • External controller
  • Printed Circuit Board (PCB)

Related codes

F.61

Your boiler has detected a technical communication error between the main control board and the gas valve, preventing it from lighting safely.

High Engineer only £180-450

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.62

Your boiler has detected a potential internal gas leak or an electrical failure that stops the gas supply from closing correctly, so it has shut down for safety.

Emergency Engineer only £250-£550

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.64

Your boiler has detected an electrical fault within its internal sensors or control board, which has caused the system to shut down for safety.

High Engineer only £120-£450

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Main PCB (Printed Circuit Board)

Related codes

Showing 21–30 of 31
F.65

Your boiler’s internal computer brain is overheating, which has caused the system to shut down for safety.

High Engineer only £250-£550

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Display Interface

Related codes

F.67

Your boiler's main control board is receiving an incorrect electrical signal from the flame sensor, meaning the system cannot safely confirm if the burner is lit.

High Engineer only £250-£450

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring loom
  • Ignition electrode

Related codes

F.70

Your boiler’s internal computer boards are having trouble communicating because they haven't been properly synced or configured to recognize each other.

High Engineer only £90-180

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • User Interface/Display PCB

Related codes

F.71

Your boiler has detected that a temperature sensor is sending a stuck or frozen reading, preventing it from heating your home or water safely.

High Engineer only £95-170

Parts commonly replaced

  • Flow Temperature Sensor (NTC)
  • Sensor Wiring Harness

Related codes

F.72

Your boiler has detected that its temperature sensors are giving conflicting or incorrect readings, causing it to shut down for safety.

High Engineer only £120-£220

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Wiring harness

Related codes

F.73

Your boiler's internal sensor that monitors water pressure has lost electrical contact or has failed, causing the system to stop working for safety.

High Engineer only £140-£250

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness
  • Main PCB

Related codes

F.74

Your boiler has detected an electrical issue with its internal water pressure sensor, meaning it cannot accurately tell if there is enough water in the system to run safely.

High Engineer only £140-£260

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness
  • Main PCB

Related codes

F.75

Your boiler has stopped working because it cannot detect the necessary change in pressure when the pump starts up.

High DIY-safe £180-350

What to check first

  1. Check the pressure gauge and top up the water to 1.5 bar if it is low
  2. Reset the boiler by holding the flame/cross button for five seconds
  3. Bleed your radiators to ensure there is no trapped air in the system

Parts commonly replaced

  • Water pressure sensor
  • Circulation pump
  • Expansion vessel

Related codes

F.76

Your boiler has detected a safety-related electrical fault within its internal wiring or a heat protection fuse, causing it to shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Overheating protection fuse
  • Wiring harness
  • Main PCB

Related codes

F.77

Your boiler is struggling to remove excess water or is experiencing a communication error with an external safety part, causing it to shut down to prevent damage.

High Engineer only £120-280

Parts commonly replaced

  • Condensate pump
  • External accessory module
  • Exhaust gas flap

Related codes

Showing 31–31 of 31
S.8

Your boiler is taking a mandatory cooling break to prevent overheating after a period of intense work.

Low DIY-safe

What to check first

  1. Wait up to 20 minutes for the status code to clear automatically
  2. Ensure radiators are turned on and TRVs are open to allow heat to dissipate
  3. Check that the system pressure is between 1.0 and 1.5 bar on the digital display

Related codes

40 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

P.0 Diagnostic Your boiler is currently running a self-cleaning routine to remove trapped air bubbles from your pipes and radiators. P.1 Diagnostic Your boiler is currently running a self-test at maximum power to ensure everything is working correctly after it has started up. P.2 Diagnostic Your boiler is currently running a background test to check that it is burning gas correctly at its lowest possible setting. P.5 Diagnostic Your boiler is currently running a programmed self-test to check that it can safely shut down if it gets too hot. P.6 Diagnostic Your boiler is currently running a maintenance program to help fill or drain the system, meaning it has temporarily paused its normal heating and hot water functions. S.0 Status Your boiler is working perfectly; it is simply in standby mode because your thermostat hasn't asked it to turn on for heating or hot water yet. S.1 Status Your boiler is currently preparing to start the fan as part of its normal ignition process. S.2 Status Your boiler is currently warming itself up and checking that water is flowing correctly before it starts heating your home. S.3 Status Your boiler is currently going through its starting sequence and is trying to ignite the flame to provide heating or hot water. S.4 Status Your boiler is operating normally and is currently in the process of heating your home or water. S.5 Status Your boiler is pausing briefly because it has finished its heating cycle or has reached the required temperature and is now cooling down internal components. S.6 Status Your boiler has paused its operation because it is not receiving the correct feedback signal from the fan that pushes exhaust gases out of the system. S.7 Status Your boiler is temporarily pausing because it has detected that water is returning to the unit too quickly or at an unexpected temperature. S.10 Status Your boiler has detected that you have turned on a hot water tap and is currently working to provide hot water to your home. S.11 Status Your boiler is currently preparing to heat your hot water by starting up its internal air extraction system. S.13 Status Your boiler is currently in the process of lighting the flame to heat your water, which is a normal part of its operation. S.14 Status Your boiler is currently heating water for your taps or shower, and this code simply indicates it is operating normally. S.15 Status Your boiler is simply finishing a safety cooling cycle after you have finished using hot water, and there is no cause for concern. S.16 Status Your boiler has detected an issue with the air fan system and has temporarily stopped heating to prevent further damage. S.17 Status Your boiler is simply performing a routine cooling-down process after you have finished using hot water, so there is no need for concern. S.21 Status Your boiler is currently going through its normal starting sequence to begin heating your water. S.23 Status Your boiler is currently struggling to light the flame it needs to provide heating and hot water. S.24 Status Your boiler is currently operating normally and is in the process of heating your radiators. S.25 Status Your boiler is currently just finishing its standard cooling-down process after heating your water and is not experiencing a fault. S.26 Status Your boiler's fan is attempting to spin, but the electronic control board isn't receiving the correct signal back to confirm it is working properly. S.27 Status Your boiler is simply finishing a hot water cycle and is running the pump briefly to move the remaining heat into your radiators. S.28 Status Your boiler is temporarily pausing its heating cycle to prevent it from switching on and off too frequently after a short period of use. S.30 Status Your thermostat has told the boiler to stay switched off because your home has reached the requested temperature or a timer has kicked in. S.31 Status Your boiler is currently set to its summer setting or is being told by your thermostat not to turn on the heating because it thinks the house is warm enough. S.32 Status Your boiler has temporarily paused operation because it detected unusual airflow that could lead to freezing or a fan issue. S.34 Status Your boiler has noticed the temperature is very cold and has automatically turned itself on to prevent the internal pipes from freezing. S.36 Status Your temperature settings are too low for the boiler to start heating, so the system is currently on standby. S.41 Status Your boiler has too much water in the system, which is causing high pressure and has triggered a safety shutdown to protect the components. S.42 Status Your boiler has paused operation because it cannot safely clear waste gases or discharge wastewater produced during the heating process. S.53 Status Your boiler has temporarily paused because the water is not flowing through the system fast enough, causing it to heat up too quickly. S.54 Status Your boiler has temporarily paused itself because it detected that the water temperature is rising too quickly, suggesting there isn't enough water circulating through the system. S.96 Status Your boiler is performing a self-diagnostic check on its internal temperature sensors and has temporarily paused heating until it confirms everything is working correctly. S.97 Status Your boiler is currently performing a self-test of its internal pressure sensor and has temporarily paused heating until it finishes. S.98 Status Your boiler is temporarily pausing to double-check that its internal temperature sensors are reading correctly before it starts heating your home. SEr Diagnostic Your boiler is simply reminding you that it is time for its scheduled annual safety check and service.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.