What the manual says
Manufacturer manualAir in the pump. Restricted CH flow due to air or a circuit restriction
DIY fix possible
Turn off the power supply to the boiler.Locate the pump screw on the front (a large flat-head screw) and carefully loosen it to bleed out trapped air until water trickles out.Retighten the screw, ensure your system pressure is topped up to 1.5 bar, and restart the boiler.