C6 on Viessmann Vitodens 333-F

Your boiler is having trouble communicating with the internal pump that manages one of your heating circuits, meaning that part of your heating may not be working correctly.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

What the manual says

Manufacturer manual

Communication fault - variable speed heating circuit pump, heating circuit M2. Control mode, max. pump speed

From this model's manual
Verified against the Viessmann Vitodens 333 F installation & service manual, page 95.
Plain-English guidance below. Severity, DIY steps, costs and parts are our interpretation to help you act, not text from the manual.

What causes this fault?

This fault occurs when the boiler's main control board loses its digital connection with the pump responsible for your secondary heating zone. The most common reason is a physical failure of the pump's internal electronics or a loose connection in the wiring that carries signals between the components.

This fault is more frequent in autumn when the heating is first turned back on, as the pump can seize or fail after being inactive throughout the summer.

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Avoid the next call-out bill

A cover plan would handle faults like C6: no call-out fees, no surprise bills.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

Related fault codes

Related guides you might find useful