Low
t4 on Worcester Bosch Greenstar CDi Compact

Your boiler is currently running a background self-test to ensure the internal component that switches between heating your radiators and heating your hot water is working correctly.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

Technical description

Three way valve test. Test the operation of the diverter valve. When 1 is selected via the test menu the diverter valve will move to the DHW position. When 0 is selected the valve will move to CH position.

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.